Dergiler / Electrica / 2006 / Cilt: 6 Sayı: 1

TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY

Sayfa
53–59
Yayın Tarihi
2012-01-02
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Strong pulsation is observed in the harmonic frequency of tissue-motion that has a relation to the heartbeat frequency of a newborn baby.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Tissue-motion is an important physical parameter that can be considered in discussing the strength of artery pulsation of newborn baby for pediatrics diagnosis.
📊
Temel Bulgular & Veri:In this paper, we have used optical flow technique to determine the tissue-motion velocity quantitatively in cranial ultrasonogram of newborn baby.
💡
Sonuç & Katkı:Strong pulsation is observed in the harmonic frequency of tissue-motion that has a relation to the heartbeat frequency of a newborn baby.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Tissue-motion · pulsation · newborn baby

Abstract

Tissue-motion is an important physical parameter that can be considered in discussing the strength of artery pulsation of newborn baby for pediatrics diagnosis. In this paper, we have used optical flow technique to determine the tissue-motion velocity quantitatively in cranial ultrasonogram of newborn baby. We have estimated the tissue-motion by using gradient-based optical flow method and then the time variant tissue motion velocities are analyzed by using Fourier transform. Strong pulsation is observed in the harmonic frequency of tissue-motion that has a relation to the heartbeat frequency of a newborn baby.

🔖

Bu Makaleye Atıf Yap

AHMAD, M., CHOWDHURY, M. Z., ALAM, M. J. (2012). TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. Electrica, Cilt: 6 Sayı: 1, 53–59. https://ajindex.com/articles/1017630

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (6)

  1. Ahmad, M., M. S. Yusuf, M. Z. Chowdhury, and M. Yamada, “Global optimization of optical flow technique on the computation of tissue-motion in neonatal cranial ultrasonogram,” Electronic Engineering, Istanbul university, vol., no. 1, pp. 1007-1016, 2004.
  2. Kearney, J. K., W. B. Thompson, and D. L. Analysis of Gradient-Based Methods with Local Optimization,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 9, pp. 244, March 1987.
  3. Fukazawa, M., H. Kubo, Y. Kitsunezuka, and M. Yamada, 1999, “Motion analysis of artery pulsation in neonatal cranial ultrasonogram,” SPIE, vol. 3661. Kitsunezuka, Y., and H. Nakamura, “Syonika-Rinsyo,” no. 38, pp. 297-308 [in Japanese], 1985.
  4. Press,
  5. W. H., Saul A. Teukolsky, William T. Vetterling and Brian P. Flannery, “Numerical Recipes in C: The art of Scientific Computing”, Second Edition, Cambridge University press. ultrasonogram,” Jpn. J. Appl. Physics. 37, pp. 1178, 1998.
  6. Yamada, M., M. Fukuzawa, Y. Kitsunezuka, J. Kishida, N. Nakamori, H. Kanamori, T. Sakurai and S. Kodama, “Pulsation detection from noisy ultrasound echo moving images of newborn baby head using Fourier transform,” Jpn. J. Appl. Phys., Vol. 34, p. 2854-2856, 1995.