Dergiler / Electrica / 2014 / Cilt: 14 Sayı: 2

NOVEL OPTIMIZED OPERATION OF WIND SYSTEM BASED SHUNT ACTIVE FILTER (W-SAF) TO MITIGATE THE CURRENT HARMONICS FOR ENERGY CONSERVATION

Sayfa
1825–1835
Yayın Tarihi
2015-03-25
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The paper presents the concept of wind power generation system inverter as SAF under balanced and un-balanced conditions.
📊
Temel Bulgular & Veri:The reference currents extract by the Fuzzy logic controller based instantaneous active and reactive power (p-q) strategy.
💡
Sonuç & Katkı:Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Wind · Shunt Active Filter (W-SAF) · conservation

Abstract

The paper presents the concept of wind power generation system inverter as SAF under balanced and un-balanced conditions. PV based systems are practically inactive during the night time, Because of the system cannot conserve the energy on the night time. During the night time, the PV-SAF provides only the compensation for the reactive power disturbance through the battery bank. The reference currents extract by the Fuzzy logic controller based instantaneous active and reactive power (p-q) strategy. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy with PI controller is unable to yield an adequate solution when source voltages are not ideal. Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller.

🔖

Bu Makaleye Atıf Yap

GOVIND, V., KARTHIKEYAN, C., RAVI, V. (2015). NOVEL OPTIMIZED OPERATION OF WIND SYSTEM BASED SHUNT ACTIVE FILTER (W-SAF) TO MITIGATE THE CURRENT HARMONICS FOR ENERGY CONSERVATION. Electrica, Cilt: 14 Sayı: 2, 1825–1835. https://ajindex.com/articles/1017473

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Akagi H, Kanazawa Y, Instantaneous (1984). Reactive Power Compensators Comprising Switching Devices without Energy Storage Components. IEEE Transactions on Industry Applications. 20(3): 625-630.
  2. Peng Z (1998). Harmonic and Reactive Power Compensation Based on the Generalized Instantaneous Reactive Power Theory for Three-Phase Four-Wire Systems. IEEE Transactions on Power Electronics. 13(5): 1174-1181.
  3. Montero M I M (2007). Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems. IEEE Transactions on Power Electronics. 22(1): 229-236.
  4. Vodyakho O, Chris Mi Senior C (2009). Three-Level Inverter- Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems. IEEE Transactions on Power Electronics. 24(5): 1350- 1363. Aredes M (1997). Three-Phase Four-Wire Shunt Active Filter IEEE Control Electronics.12(2): 311-318. Transactions on Power [6]. Akagi (2007). Instantaneous Power Theory and Applications to Power Conditioning. IEEE Press/Wiley-Inter- Science Mikkili S, Panda A K (2011). Instantaneous Active and Reactive Power and Current Strategies for Current Harmonics Cancellation in 3-ph 4Wire SHAF with Both PI and Fuzzy Controllers. Journal of Energy and Power Engineering. 3(3): 285-298.
  5. Salmeron P, Herrera R S (2006). Distorted and Unbalanced Systems Compensation within Instantaneous Reactive Power Framework. IEEE Transactions on Power Delivery. 21(3): 1655-1662.
  6. Mikkili S, Panda A K (2011). SHAF for Mitigation of Current Harmonics Using p-q Method with PI and Fuzzy Controllers. Engineering, Technology & Applied Science Research, 1(4): 98-104.
  7. Patel, M.R. (1999) “Wind and solar power systems: Design, Analysis and Operation”, Second Edition,
  8. CRC Press LLC, N.W. Corporate Blvd., Boca Raton, Florid. Johnson, G.L. “Wind Energy systems”, England Cliffs: Prentice-Hall, 2001.
  9. Gieras, J. and Wing, M (2002) “Permanent Magnet Motor Technology: Design and Applications”, Second Edition,
  10. CRC Press LLC, N.W. Corporate Blvd., Boca Raton, Florida. Mohan, N., Undeland, T.M. and Robbins, W.P. (2006) “Power Electronics Converters: Applications and Design”, Third Edition, Jhon Wiley & Sons Asia Pte. Ltd., Singapore:172-178,
  11. Rashid, M.H. (2203). “Power Electronics Circuits, Devices and Applications,” Second Edition,
  12. Prentice-Hall of India Private Ltd, New Delhi. Elgendy, M.A., Zahawi, B. and Atkinson D.J. (2012), “Assessment of perturb and observe MPPT algorithm implementation applications”, IEEE Transaction on Sustainable E