Dergiler / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2017 / Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

ESTIMATION OF THE MEASUREMENT UNCERTAINTY OF DIGOXIN

Sayfa
295–295
Yayın Tarihi
2017-02-16
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Moreover, labratories should report patient’s result with the measurement uncertainty values to clinicians.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A measurement result is complete only when accompanied by a quantitative statement of its uncertainty.
📊
Temel Bulgular & Veri:The aim of this study is to calculate measurement uncertainty of digoxin parameter by using internal and external quality control data and to compare these calculated measurement uncertainties with CLIA and RILIBAK’s total error % (TEa%) value.In the calculation of measurement uncertainty, six step “uncertainty calculation model, that is defined in Nordest guide which is based on European Accreditation Guideline / 12 /.
💡
Sonuç & Katkı:Moreover, labratories should report patient’s result with the measurement uncertainty values to clinicians.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:ESTIMATION OF THE MEASUREMENT UNCERTAINTY OF DIGOXIN

Abstract

A measurement result is complete only when accompanied by a quantitative statement of its uncertainty. The uncertainty is required in order to decide if the result is adequate for its intended purpose and to ascertain if it is consistent with other similar results. The aim of this study is to calculate measurement uncertainty of digoxin parameter by using internal and external quality control data and to compare these calculated measurement uncertainties with CLIA and RILIBAK’s total error % (TEa%) value.In the calculation of measurement uncertainty, six step “uncertainty calculation model, that is defined in Nordest guide which is based on European Accreditation Guideline / 12 /. European Tecnical Report: 1 / 3 and ISO / DTS 21748 Guideline /8/ was used. Last six months internal and external datas were used for calculations.TEa % values for Digoxin was 9,33. This value was not higher than TEa % value of RILIBAK (TEa%30) and CLIA (TEa%20).Drug analysis are important for follow-up of patients so their correct measurements are critical. However as far as our knowledge measurement uncertainity of drugs were not common Laboratories should use same guideline for standardization of measurement uncertainty and gave results lower than TEa% thats measurement uncertainty is calculated according to the same guideline. Moreover, labratories should report patient’s result with the measurement uncertainty values to clinicians.

🔖

Bu Makaleye Atıf Yap

BARAN, P., BAL, C., TURHAN, S., ŞEN, O., EREL, O. (2017). ESTIMATION OF THE MEASUREMENT UNCERTAINTY OF DIGOXIN. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 295–295. https://ajindex.com/articles/1009397

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. P. BARAN, C. BAL, S. TURHAN, O. ŞEN, O. EREL Ankara Ataturk Education and Research Hospital, Clinical Biochemistry, Ankara, Turkey