Dergiler / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2017 / Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

CHARACTERIZATION OF ION IMPRINTED BASED NANOSENSOR FOR REAL TIME DETECTION OF Cu(II) IONS

Sayfa
277–277
Yayın Tarihi
2017-02-16
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Several parameters, such as pH, initial ion concentration and selectivity will be investigated to obtain the optimum conditions of nanosensor efficiency.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:There are several trace elements in human body.
📊
Temel Bulgular & Veri:However, at elevated concentrations, Cu (II) can react with molecular oxygen to generate reactive oxygen species (ROS), suggesting their potential damage to biomolecules.
💡
Sonuç & Katkı:Several parameters, such as pH, initial ion concentration and selectivity will be investigated to obtain the optimum conditions of nanosensor efficiency.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:CHARACTERIZATION OF ION IMPRINTED BASED NANOSENSOR FOR REAL TIME DETECTION OF Cu(II) IONS

Abstract

There are several trace elements in human body. Among these trace elements, Cu (II) plays an essential role in physiological processes in certain amounts. However, at elevated concentrations, Cu (II) can react with molecular oxygen to generate reactive oxygen species (ROS), suggesting their potential damage to biomolecules. In this regard, the residual level of Cu (II) in drinking water is restricted. The United States Environment Protection Agency (USEPA) sets a maximum contaminant level (MCL) of Cu (II) at 1.3 ppm (20 mM) in drinking water with regards to its toxicity. Therefore, it is important to develop highly sensitive and selective analytical methods for Cu (II) detection. In aim of this study, for the first time, is to detect Cu (II) ions quantitatively in real time with high sensitivity and selectivity without any laboratory conditions and expensive instruments. The study targets to prepare a gravimetric nanosensor for the analysis of Cu (II) ions by combining the excellent selectivity properties of ion imprinted polymers (IIPs) and nanotechnology. Thus, Cu (II) imprinted IIP nanoparticles in a size range of 60 nm were prepared in the presence of N-methacryloyl-L-histidine functional monomer with 2:1 and 1:1 mol ratio. They were characterized by scanning electron microscopy (SEM), zeta size distribution analysis and FTIR spectroscopy. Cu (II) imprinted IIPs was then adapted to quartz crystal microbalance (QCM) nanosensor for the real time detection of Cu (II) ions in aqueous solutions. Several parameters, such as pH, initial ion concentration and selectivity will be investigated to obtain the optimum conditions of nanosensor efficiency.

🔖

Bu Makaleye Atıf Yap

AYDOĞAN, N., ANDAÇ, M., DENIZLI, A. (2017). CHARACTERIZATION OF ION IMPRINTED BASED NANOSENSOR FOR REAL TIME DETECTION OF Cu(II) IONS. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 277–277. https://ajindex.com/articles/1009295

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Nihan AYDOĞAN, Müge ANDAÇ, Adil DENIZLI Hacettepe University, Environmental Engineering Department, 06800 Ankara,
  2. Turkey Hacettepe University, Chemistry Department, 06800 Ankara, Turkey