Dergiler / TOJSAT / 2015 / Cilt: 5 Sayı: 3

The Effect of Magnetic Treatment on Retarding Scaling Deposition

Dergi
TOJSAT
Sayfa
62–77
Yayın Tarihi
2016-07-23
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Nonetheless, further investigation is recommended to optimize magnetic power, flow rate and operating temperature

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The magnetic treatment method has been applied as a scale deposition controlling and/or preventing tool for several decades in the domestic and industrial water systems.
📊
Temel Bulgular & Veri:However, the attention paid to magnetic treatment has increased during the last years as a prevention method.
💡
Sonuç & Katkı:Nonetheless, further investigation is recommended to optimize magnetic power, flow rate and operating temperature
🔬Tür:Uygulamalı Anket & Alan Araştırması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Barium sulfate (BaSO4) · Calcium Carbonate (CaCO3) · Calcium Sulfate (CaSO4)

Abstract

The magnetic treatment method has been applied as a scale deposition controlling and/or preventing tool for several decades in the domestic and industrial water systems. However, most of the scientific communities have remained skeptical about the viability of this water treatment method. However, the attention paid to magnetic treatment has increased during the last years as a prevention method. Hence, a literature review was carried out to seek both positive and negative results. However, a review of the available literature is rather confusing. An experimental laboratory study on the effect of magnetic treatment method was conducted at the Kuwait Institute for Scientific Research's (KISR's) Doha Laboratory for reverse osmosis plant to investigate the effect of magnetic treatment in preventing and/or retarding scaling. Thus, the effect of magnetic treatment in retarding calcium carbonate, calcium sulfate and barium sulfate scaling was investigated within two different configurations (open and closed loop) and by using different techniques at ambient temperature. The current paper summarizes the literature survey and expresses the results of experimental work. The results showed that the magnetic treatment was effective in increasing the retention time required for scaling. Nonetheless, further investigation is recommended to optimize magnetic power, flow rate and operating temperature

🔖

Bu Makaleye Atıf Yap

Salman, M. A., Safar, M., Nuwaibit, G. A. (2016). The Effect of Magnetic Treatment on Retarding Scaling Deposition. TOJSAT, Cilt: 5 Sayı: 3, 62–77. https://ajindex.com/articles/1008428

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Martynova O. I., Tebenekhin, E. F. and Gusev. B. T. (1967). Conditions and mechanism of deposition of thesolid calcium carbonate phase from aqeuous [sic] solutions under the influence of a magnetic field.Colloid Journal of Russian Academy of science, 29; 512-514.
  2. Boichenko V. A. and Sapogin. L. G. (1977). Theory of magnetic water treatment. Journal of Engineering Physics and Thermophysics, 33 (2); 350-355.
  3. Grutsch J. F. and McClintock. J. W. (1984). Corrosion and deposit control in alkaline cooling water usingmagnetic water treatment at AMOCO's largest refinery. Corrosion 84 paper no 330 Busch K. W., Busch, M. A. Parker; D. H. Darling, R. E. and Mc Atee Jr. J. L. (1986). Studies of awater treatment device that uses magnetic fields. Corrosion, 42 (4); 211-221., Ronald G.; Ziqi, A. Z. James, A. F. and Ram S. R. (1995). Reduction of soluble mineral concentrations inCaSO4 saturated water using a magnetic field. Water Research, 29 (3); 933-940.
  4. Baker J. S., Judd, S. J. and Parsons S. A. (1997). Antiscale magnetic pretreatment of reverse osmosis feedwater. Desalination 110: 151-166.
  5. Barrett R. A. and Parsons. S. A. (1998). The influence of magnetic fields on calcium carbonate precipitation. Water Research, 32 (3); 609-612.
  6. Gabrielli C., Jaouhari, R. Maurin, G. and Keddam, M. (2000). Magnetic water treatment for scale prevention. Water Resources 35 (13); 3249-3259.
  7. Gryta M. (2011). The influence of magnetic water treatment on CaCO3 scale formation in membrane distillation process. Separation and Purification Technology, 80; 293–299.
  8. Freitas, A. M. B, Landgrave, F. J. G. Nvlt, J. and M. Giulietti. (2000). Effect of magnetic field on the crystallization of zinc sulfate. Brazilian Journal of Chemical Engineering, 17:111-115. Kobe S.; Drazic, G. McGuiness, P. J. and Strazisar, J. (2001). The influence of the magnetic field on the crystallization form of calcium carbonate and the testing of a magnetic water treatment device. Journal of Magnetism and Magnetic Materials, 236 (1-2); 71-76.
  9. Kobe S., Drazic, G. Cefalas, A. C. Sarantopoulou, E. and Strazisar, J. (2002). Nucleation and crystallization of CaCO3 in applied magnetic fields. Crystal Engineering 5 (3-4); 243-253.
  10. Knez S. and Pohar, C. (2005). The magnetic field influence on the polymorph composition of CaCO3 precipitated from carbonized aqueous solutions. Colloid and Interface Science, 281; 377-388.
  11. Saban K. V., Jini, T. and Varghese, G. (2005). Impact of magnetic field on the nucleation and morphology of calcium