Dergiler / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2017 / Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE

Sayfa
117–117
Yayın Tarihi
2017-02-16
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The proposed electrode was applied to the determination of TA in tea sample with satisfactory results.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study the selective determination of tannic acid (TA) was performed using a glassy carbon (GC) electrode modified with 1-Benzoyl-3-(pyrrolidine) thiourea (PrTu).
📊
Temel Bulgular & Veri:PrTu-GC electrode demonstrated an electrocatalytical effect on the oxidation of TA using differential pulse voltammetry (DPV) method in 0.1 M Britton Robinson (BR) buffer solution of pH 2.
💡
Sonuç & Katkı:The proposed electrode was applied to the determination of TA in tea sample with satisfactory results.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE

Abstract

In this study the selective determination of tannic acid (TA) was performed using a glassy carbon (GC) electrode modified with 1-Benzoyl-3-(pyrrolidine) thiourea (PrTu). PrTuwas deposited on the GC electrode in nonaqueous media by cyclic voltammetry. PrTu-GC electrode demonstrated an electrocatalytical effect on the oxidation of TA using differential pulse voltammetry (DPV) method in 0.1 M Britton Robinson (BR) buffer solution of pH 2. Under optimum conditions linear calibration graphs were obtained over the TA concentration range 2.0×10−6 to 4.2×10−5 M. The detection of limit (LOD) was found as 0.6 µM. The proposed electrode was applied to the determination of TA in tea sample with satisfactory results.

🔖

Bu Makaleye Atıf Yap

ÇALIK, E., UZUN, D., YILMAZ, Ü. T. (2017). SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 117–117. https://ajindex.com/articles/1008372

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Elif ÇALIK, Demet UZUN, Ümmihan Taşkoparan YILMAZ Gazi University, Polatlı Science and Art Faculty, Department of Chemistry, 06900 Polatlı, Ankara/Turkey Gazi University, Science Faculty, Department of Chemistry, 06500, Ankara/Turkey