C3-C4-Ig A-Ig G-Ig M levels in gonarthrosis were measured before "was-out" and theree months later in synovial fluid, and the values were compared with the control group. The levels found for Ig A and Ig G were significantly lower then in the control group and alsd pain disapeared in the patients while the C3-C4 and Ig levels remanied the same. The disturbance in permeabilty and complement fixation of the tissue was thought to be the reason of the high levels.

Özet

Gonartrosda Artroskopik "Wash-Out" öncesi ve 3 ay sonrası, eklem sıvısındı C3-C4-Ig A-Ig G-Ig M seviyeleri saptanmış ve kendi aralarında ayrıca kontrol grubu ile karşılaştırılmıştır. Post wash-out sıvısında Ig A ve Ig G’de Kontrol Grubu’ununda altına inen anlamlı bir düşüş görülmüş ve hastaların ağrı şikayetlerinde azalma belirlenmiştir. C3-C4 ve Ig M’deki seviye farkının aynı kalması, permaabilite bzukluğu olan dokuların komplementi fikse etmesine bağlanmıştır.