Heat exchangers used inside heat engines become a crucial role on efficiency and thermal performance of combi boilers. It has to be known that how design parameters of heat exchanger have effects over its capacity in order to produce combi boilers in accord with ERP regulations. When these effects are determined, design is to be improved in terms of time and cost owing to the fact that heat engine’s thermal system inside the combi boiler is modelled numerically and correctly. In this study, effects of design parameters of condense boiler’s heat exchanger on capacity were evaluated numerically by ANSYS Programme.

Özet

Kombilerin ısıl performansında ve enerji verimliliği üzerinde, yanma ünitelerinin içerisinde kullanılan ısı değiştiricileri önemli bir rol oynamaktadır. ERP (Energy Related Products, Enerji İlişkili Ürünler) regülâsyonlarına uygun kombilerin üretilebilmesi için ısı değiştirici tasarım parametrelerinin ısı değiştirici kapasitesi üzerindeki etkilerinin bilinmesi gerekmektedir. Bu etkilerin belirlenmesi sırasında, kombinin yanma ünitesi içerisindeki ısıl sistemin doğru bir şekilde sayısal olarak modellenmesi, tasarım sürecini zaman ve maliyet açısından iyileştirecektir. Bu çalışmada, yoğuşmalı bir kombiye ait ısı değiştiricisinde belirlenen tasarım parametrelerinin kapasiteye etkisi ANSYS programı kullanılarak sayısal olarak incelenmiştir.

Keywords: Kombi, ısı değiştirici