Journals / Türk Otolarengoloji Arşivi / 2007 / Cilt: 45 - Sayı: 4
Comparison of noise levels in six hospitals in İstanbul
- Journal
- Türk Otolarengoloji Arşivi
- Pages
- 206–212
- DOI
- —
Abstract
Objectives: To determine the noise levels in six hospitals in Istanbul and to emphasize the negative effects of noise in hospital environment. Methods: In this study sound levels were measured at two university hospitals and four training and education hospitals in Istanbul. Measurements were performed between 08.15- 16.00 am. during the outpatient settings with one hours period. Noise levels were measured as sound pressure level dB (SPL dB) with sound level meter by using A weighted setting within the frequency band of middle and high that human ear is most sensitive. Results: All of the hospitals were found to have average noise levels higher than 40 dB (the upper limit of Noise Control Regulations). (p
Özet
Amaç: İstanbul’da bulunan altı büyük hastanedeki gürültü düzeyini ölçmek ve hastane ortamında gürültünün olumsuz etkilerine dikkat çekmektir. Yöntem: Bu çalışmada İstanbul’daki iki üniversite hastanesi ve dört eğitim ve araştırma hastanesi genel poliklinik salonunda ses düzey ölçümleri yapıldı. Ölçümler 08.15-16.00 saatleri arasında, yani poliklinik hizmetinin verildiği süre içerisinde birer saatlik periyotlarda yapıldı. Gürültü miktarı, ses düzeyi ölçer ile ses basınç seviyesi desibel (SPL dB) olarak ölçüldü ve insan kulağının en çok hassas olduğu orta ve yüksek frekansların özellikle vurgulandığı A ağırlıklı düzenleme kullanıldı. Bulgular: Ölçümler sonucu hastanelerin tamamında Gürültü Kontrol Yönetmeliğinin üst sınır düzey olarak belirlediği 40 dB’nin üzerinde değerler saptandı (p