Abstract
Objective: More than 70% of medical laboratory errors occur in the pre-analytical phase. Analysis and recording of errors are necessary for evaluation and prevention of errors. We aimed to evaluate the phases of pre-analytical errors of microbiology laboratory and classify them according to six sigma approaches. Material and Methods: Samples which were considered inappropriate for the analysis at the medical microbiology laboratory were evaluated under the three headings as error categories, hospital units and laboratory areas where the analyses were done. Error ratio in one million was determined, and expressed on a sigma scale. The calculated sigma values were classified as follows: “very good”, ≥5.0; good, 4.0-5.0; minimum, 3.0 and
Özet
Amaç: Tıbbi laboratuvar hatalarının %70’inden fazlasıpreanalitik evrede gerçekleşmektedir. Hataların analizi vekayıt altına alınması, durum değerlendirilmesi ve hatalarınönlenebilmesi için gereklidir. Çalışmamızda mikrobiyolojilaboratuvarı preanalitik evre hataları değerlendirilerek altısigma yaklaşımı ile değerlendirilmesi sınıflanmasıamaçlandı.Gereç ve Yöntem: Tıbbi Mikrobiyoloji Laboratuvarı’ndaanaliz için uygun olmadığı saptanan numuneler, hatakategorileri, örneklerin geldiği hastane birimleri ve analizigerçekleştirilen laboratuvar alanları olmak üzere üç anabaşlık altında sınıflandırıldı. Bunun için milyonda hataoranı saptanarak sigmametrik hesaplama yapıldı.Hesaplanan değerler ≥5.0 ise çok iyi, 4.0-