Journals / Türk Kardiyoloji Derneği Arşivi / 2020 / Cilt: 48 - Sayı: 1

A broken, O-shaped catheter during coronary angiography:Percutaneous retrieval via femoral approachusing a wire-balloon technique

Koroner anjiyografi esnasında kırılarak “O” şeklini almış kateter: “Tel-balon” tekniği ile femoral yaklaşımın kullanıldığı perkütan yolla dışarı alınması

Pages
64–66
DOI
—

Abstract

Entrapment of equipment during coronary angiography is an uncommon but serious complication of invasive coronary procedures. Percutaneous extraction of trapped material is the accepted method of treatment. This case report is a description of the extraction of a diagnostic catheter retained as a result of collapsing into an O-shape in the right common iliac artery while trying to engage the tip of the catheter with the right coronary ostium. This rationale and unique wire-balloon method, requiring no specifically designed device, can be simply and safely performed in similar cases.

Özet

Koroner anjiyografi esnasında kullanılan malzemelerin hapsolması invaziv koroner işlemlerin nadir görülen fakat ciddi komplikasyonlarından biridir. Perkütan yolla sıkışmış malzemelerin çıkarılması kabul görmüş tedavi yöntemidir. Biz de burada koroner anjiyografi esnasında sağ koroner artere selektif olarak oturmaya çalışırken sağ arteria iliaca comminis’te “O” şeklinde kıvrılarak hapsolan diyagnostik kateterin çıkarılması işlemini sunuyoruz. Rasyonel ve özgün olan ve spesifik her hangi bir malzeme gerektirmeyen bu tel-balon metodu benzer olgularda basit ve güvenilir şekilde uygulanabilir.