Anti-HDV enzyme immunoassay index in predicting HDV viremia in serum samples

Pages
294–298
DOI
—

Abstract

To determine whether the total anti-delta antibody enzyme immunoassay (EIA) test results can be used to predict viremia. Materials and methods: The EIA index value of an anti-delta total antibody assay was determined in 76 serum samples obtained from 67 patients positive for the anti-hepatitis delta virus (HDV) antibody. The presence of HDV RNA was investigated by reverse transcriptase polymerase chain reaction (RT-PCR). The relation between the RT-PCR result and EIA index was evaluated by ROC analysis. Results: Of the 76 total samples, 56 (74%) anti-HDV-positive samples were found to be PCR-positive. The samples with EIA index values below 75.75 were PCR-negative, while samples with index values above 102.55 were PCR-positive. When HDV RNA presence is considered as the gold standard, the sensitivity, specificity, and positive and negative predictive values of the chosen EIA index (100.10) in predicting viremia were 93%, 80%, 93%, and 76%, respectively. Conclusion: HDV RNA is the most reliable marker for the diagnosis of active HDV infection, and EIA index value is closely related to viral RNA presence.

Özet

To determine whether the total anti-delta antibody enzyme immunoassay (EIA) test results can be used to predict viremia. Materials and methods: The EIA index value of an anti-delta total antibody assay was determined in 76 serum samples obtained from 67 patients positive for the anti-hepatitis delta virus (HDV) antibody. The presence of HDV RNA was investigated by reverse transcriptase polymerase chain reaction (RT-PCR). The relation between the RT-PCR result and EIA index was evaluated by ROC analysis. Results: Of the 76 total samples, 56 (74%) anti-HDV-positive samples were found to be PCR-positive. The samples with EIA index values below 75.75 were PCR-negative, while samples with index values above 102.55 were PCR-positive. When HDV RNA presence is considered as the gold standard, the sensitivity, specificity, and positive and negative predictive values of the chosen EIA index (100.10) in predicting viremia were 93%, 80%, 93%, and 76%, respectively. Conclusion: HDV RNA is the most reliable marker for the diagnosis of active HDV infection, and EIA index value is closely related to viral RNA presence.

Keywords: Key words: Anti-HDV enzyme immunoassay, ROC analysis, HDV RNA, reverse transcriptase polymerase chain reaction