Journals / Turkish Journal of Electrical Engineering and Computer Sciences / 2018 / Cilt: 26 - Sayı: 3

A new method for detecting jittered PRI in histogram-based methods

Pages
1214–1230
DOI
—

Abstract

Histogram-based methods are among the best methods for deinterleaving, because of their easy implementation. However, they have a basic defect when they encounter a jittered pulse repetition interval (PRI). Jittered PRI is one of the most sophisticated patterns for electronic warfare (EW) receivers. In jittered PRI, the time among successive pulses varies in a totally random manner; thus its detection is very complicated. In this paper we present a new method for extracting jittered PRI from histogram-based methods. Simulation results demonstrate excellent performance of the proposed method in normal as well as hard circumstances where a higher missing pulse rate occurs or even when several targets with PRI of type jitter exist.