Journals / Journal of Thermal Engineering / 2020 / Cilt: 6 - Sayı: 6
PREDICTING BOILER EFFICIENCY DETERIORATION USING ENERGY BALANCE METHOD: CASE STUDY IN 660 MW POWER PLANT JEPARA, CENTRAL JAVA, INDONESIA
- Pages
- 247–256
- DOI
- —
Abstract
This research aims to determine the deterioration of boiler efficiency in Tanjung Jati B Unit 3 and 4 coal-fired power plant with capacity 2x660 MW in Jepara Central Java Indonesia using energy balance (indirect method) based on ASME PTC 4-2018. The deterioration of boiler efficiency per year estimated using linear regression. From the results of the research, it is found that the deterioration in boiler efficiency of unit 3 is 0.19% per year and unit 4 is 0.44% per year. Large heat losses that vary for each performance test are greatly influenced by the use of various coal properties.