Pnömatik Distansiyona Bağlı Bilateral Peroneal Sinir Hasarı
- Pages
- 271–274
- DOI
- —
Abstract
Peroneal nerve injury is the most commonly seen peripheral entrapment neuropathy of thelower extremities. Peroneal nerve can be exposed to pressure applied by the mechanicalexternal forces while turning around the head of fibula at he backside of it, on the way todown. A case of bilateral peroneal nerve injury which happened due to pneumatic distantionafter the operation of cerebral aneursym is presented. The possibility of compressing theperoneal nerve at the head of fibula should be considered when applying pneumatic devices inIntensive Care Units to unconscious patients.
Özet
Peroneal sinir hasarı alt ekstremitelerin en sık görülen periferik sinir tuzak nöropatisidir.Peroneal sinir fibula başının arkasından aşağıya doğru çevresini dönerken mekanik dışgüçlerle basıya maruz kalabilir. Serebral anevrizma ameliyatı sonrası pnömatik distansiyonabağlı bilateral peroneal sinir hasarı olan bir olgu sunulmuştur.Bilinci yerinde olmayan YoğunBakım Ünitesi hastalarında pnömatik cihaz uygulandığında peroneal sinirin fibula başındakomprese olma olasılığı hesaba katılmalıdır.