Journals / İstanbul Medical Journal / 2018 / Cilt: 19 - Sayı: 2
Comparison of Keratometry, Central Corneal Thickness, and Anterior Chamber Depth Results Measured With Nidek-AL Scan Biometry and Sirius Topography Devices
- Journal
- İstanbul Medical Journal
- Pages
- 158–161
- DOI
- —
Abstract
Introduction: To investigate whether the central corneal thickness (CCT), anterior chamber depth (ACD), and keratometric measurements change according to biometric and topographic measurements in childhood and in young adult age. Methods: In total, 147 eyes of 78 patients were included in the study. Patients with an ocular disease other than refractive error were not included in the study. CCT, ACD, and keratometry values of all patients were measured with Nidek-AL Scan optical biometry and Sirius combined Scheimpflug-Plasido disc Corneal Topography devices. Results: Of the seventy-eight patients, 46 were female and 32 were male. The mean age was 14.46±5.15 years (range, 5-29 years), the mean spherical equivalence was -0.30±1.13 diopters (D), and the mean axial length was 23.28±0.77 mm. The Sirius and AL-Scan CCT were 555.66±39.58 µm and 548.01±38.14 µm, respectively. The Sirius and AL-Scan ACD were 3.65±0.28 mm and 3.57±0.26 mm µm, respectively. The Sirius SimK, AL-Scan K 2.4 mm, and AL-Scan K 3.3 mm values were 43.09±1.45 D, 43.22 ±1.50 D, and 43.2±1.47 D, respectively. The values of CCT and ACD measured on the Sirius device were found to be statistically significantly higher than those measured by the ALScan device (p=.00). A high level of correlation was found between the Sirius CCT and the AL-Scan CCT (p=0.000, r=0.974). A high level of correlation was found between the Sirius ACD and AL-Scan ACD (p=0.000, r=0.918). A high level of correlation was found between the the Sirius SimK value and the AL-Scan K 2.4 mm and K 3.3 mm values (p=0.000, r values were 0.979 and 0.982, respectively). Conclusion: In childhood and young adult age, between the Sirius and AL-Scan devices, although CCT, ACD, SimK, and 2.4-3.3 mm K were statistically different, a high correlation and agreement were found between the measurements.
Özet
Amaç: Çocukluk ve genç erişkin çağında, merkezi kornea kalınlığı(MKK), ön kamara derinliği (ÖKD) ve keratometrik ölçümlerin biyometrikve topografik ölçüme göre değişim gösterip göstermediğiniaraştırmak.Yöntemler: Yetmiş sekiz hastanın 147 gözü çalışmaya dahil edildi.Refraksiyon kusuru dışında oküler hastalığı bulunan hastalar çalışmayadahil edilmedi. Tüm hastaların MKK, ÖKD ve keratometri değerleriNidek AL Scan optik biyometri ve Sirius kombine Scheimpflug-Plasidodisk Kornea Topografi cihazları ile ölçüldü.Bulgular: Yetmiş sekiz hastanın 46’sı kadın, 32’si erkek idi. Ortalamayaş 14,46±5,15 yıl(5-29 yaş arası),ortalama sferik eşdeğer -0,30±1,13diyoptri(D), ortalama aksiyel uzunluk 23,28±0.77 mm saptandı. SiriusMKK 555,66±39.58 µm, AL-Scan MKK 548,01±38,14 µm saptandı. SiriusÖKD 3,65±0,28 mm, AL-Scan ÖKD 3,57±0,26 mm saptandı. SiriusSimK 43,09±1,45 D, AL-Scan K 2.4 mm 43,22±1,50 D, AL-Scan K 3.3mm43,2±1,47 D saptandı. Sirius cihazında ölçülen MKK ve ÖKD değerleri,AL Scan cihazından ölçülen değerlere göre istatistiksel olarak anlamlıdüzeyde daha yüksek saptandı (p=0,00). Sirius MKK ile AL-Scan MKKarasında yüksek düzeyde korelasyon saptandı(p=0.000,r=0.974). SiriusÖKD ile AL-Scan ÖKD arasında yüksek düzeyde korelasyon saptandı(p=0.000,r=0.918). Sirius SimK değeri ile AL-Scan K 2.4mm veK 3.3mm arasında yüksek düzeyde korelasyon saptandı (p=0.000, rdeğerleri sırasıyla 0.979 ve 0.982 saptandı).Sonuç: Çocukluk ve genç erişkin çağında, Sirius ve AL-Scan cihazlarıarasında MKK, ÖKD, SimK ile 2.4-3.3 mm K değerleri istatistikselolarak farklı saptanmış olmasına rağmen ölçümler arasında yüksekkorelasyon ve uyum saptandı.