Journals / Istanbul University Journal of Electrical and Electronics Engineering / 2009 / Cilt: 9 - Sayı: 1
Open switch faults detection and localization algorithm for three phase shunt active power filter based on two level voltage source inverter in main power supply constant and variable frequency conditions
- Pages
- 841–851
- DOI
- —
Abstract
This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimised fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. A new fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyse and validate error signals. A Hysteresis Control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.