Eight generators (units) with total established power of 1330 MW are being used at Keban Hydroelectricity Plantfor electricity production. Each of these units are supported with a turbine guide bearing, one generator bearingan done thrust bearing. The lubricant film in the bearings and its cooling is essential and requires engineeringcalculations. In this study heat converters used in order to cool the lubricant which is warms up in the turbineguide bearing are examined. In the experiments that were conducted, the cooling conditions of the copper-pipedserpentine in unit 6 which cools turbine guide bearing and the plated exchanger in unit 8 were compared. Theexperiments were conducted under real operating conditions and these two types of coolers were compared. Inaddition, flow in the opposite plate number of different experiments were performed. Better cooling was foundoptimum number of plates.
Özet
Keban Hidroelektrik Santralinde elektrik üretimi için, toplam kurulu gücü 1330 MW olan 8 adet Generatör(ünite) kullanılmaktadır. Ünitelerin her biri bir adet türbin kılavuz yatak, bir adet generatör kılavuz yatak ve biradet taşıyıcı yatakla desteklenmektedir. Yataklardaki yağ filmi ve soğutulması önemlidir ve mühendislikhesapları gerektirmektedir. Bu çalışmada, türbin kılavuz yatakta ısınan yağı soğutmak için kullanılan ısıdeğiştirgeçleri ele alınmıştır. Yapılan deneylerde türbin kılavuz yataklarını soğutan, ünite 6da bulunan bakırborulu serpantin ile ünite 8de bulunan plakalı eşanjörün soğutma şartları karşılaştırılmıştır. Deneyler gerçekçalışma koşullarında yapılarak bu iki soğutucu tipi karşılaştırılmıştır. Ayrıca zıt akışta farklı plaka sayılarındadeneyler yapılarak daha iyi soğutma yapılabilmesi için optimum plaka sayısı tespit edilmiştir.