Journals / European oral research (Online) / 2021 / Cilt: 55 - Sayı: 1

Bond strength of metal brackets to feldspathic ceramic treated with different surface conditioning methods: an in vitro study

Pages
1–7
DOI
—

Abstract

PurposeTo compare MEP which is originally manufactured for increasing bond strengthbetween organic resins and ceramic with conventional surface treatment methodsin preparation of leucite-reinforced FC surfaces regarding shear bond strength (SBS)of stainless steel brackets and the mode of bond failure.Materials and MethodsForty specimens that were fabricated from FC material and glazed were randomlyassigned to four surface conditioning methods: (1) CoJet Sand; (2) MEP; (3) HF acidetching followed by silane coupling agent; (4) Diamond bur followed by silanecoupling agent. The SBS was determined using universal testing machine. Bondfailure sites were classified according to Adhesive Remnant Index (ARI).ResultsNo statistically significant difference (p>0.05) was found in SBS between the groupswhile significant intergroup differences were detected concerning ARI scores(p