Journals / Annals of Medical Research / 2019 / Cilt: 26 - Sayı: 8
Healing of surgical wounds treated with 810nm, 940nm, and 980nm diode lasers in different operation modes
- Journal
- Annals of Medical Research
- Pages
- 1647–1654
- DOI
- —
Abstract
Aim: The aim of the present study was to analyze the comparative effectiveness of the diode lasers having 3 different wave-lengths(810nm, 940nm, 980nm) and also the different application modes on the cellular basis in animal models.Many surgical instrumentslike scalpel, electrosurgery, and different laser types can be used for surgical incisions. Each of these have their own advantages anddisadvantages.Material and Methods: 10 mm in length and 1 mm in depth dorsal skin incisions were created on 18 male Wistar albino rats via 3different laser wave-lengths: 810nm (Gigaa, Cheese, China), 940nm(Epic 10, Biolase, USA) and 980nm (SIROlaser Advance, Sirona,Bensheim, Germany). The animals were sacrificed at either post-operative 24 hours, 3 days or 1 week. All incision sites were removedby excisional biopsies and the samples underwent histopathological evaluation.Results: There were no statistically significant differences in thermal changes, inflammation, and fibrosis in all wave-length groups(p>0.05). The chopped mode of irradiation of all wave-lengths showed significant increase in epithelial closure following theoperation (p