K-shell fluorescence yields wK were measured for the elements Ti, V, Cr, Fe, Co, Ni, Cu and F and Cl compounds of these elements. Measurements were carried out at 10 keV excitation energy using secondary excitation method. K x-rays emitted by samples were counted by a Si(Li) detector with 160 eV resolution at 5.9 keV. Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.
Özet
K-shell fluorescence yields wK were measured for the elements Ti, V, Cr, Fe, Co, Ni, Cu and F and Cl compounds of these elements. Measurements were carried out at 10 keV excitation energy using secondary excitation method. K x-rays emitted by samples were counted by a Si(Li) detector with 160 eV resolution at 5.9 keV. Measurement of K-shell fluorescence yields wK for these elements are compared with earlier experimental results obtained by other methods.