Journals / Turkish journal of vascular surgery / 2019 / Cilt: 28 - Sayı: 1
Bilateral endovascular uterine artery embolization for dysfunctional uterine artery bleeding with heartware left ventricular assist support device
- Pages
- 51–54
- DOI
- —
Özet
We report a 40-year-old lady with post-partum cardiomyopathy for more than 4 years and had left ventricular assist device (LVAD)implantation. She was New York Heart Association Class IV and Interagency Registry for Mechanically Assisted Circulatory Support LevelI. She had HeartWare (HeartWare Inc, Framingham, MA, USA) LVAD implantation. She was admitted to emergency department withdysfunctional uterine bleeding with a hemoglobin level 3 gr/dL and a hematocrit level 10%, 3 months postoperatively. The ultrasonographicevaluation revealed blood coagulum in the uterine cavity, she was diagnosed with dysfunctional uterine bleeding, and hospitalized. Sincethere was a probability of LVAD pump thrombosis, a surgical intervention was not planned. Gonadotropin releasing hormone analoguetherapy and embolisation of bilateral uterine arteries prevented further dysfunctional uterine bleeding. We report the first case in theliterature with advanced heart failure supported with LVAD and bilateral uterine artery embolization due to dysfunctional uterus arterybleeding with an endovascular procedure.