Investigation of short column effect of buildings

Binalarda kısa kolon etkisinin incelenmesi

Pages
133–139
DOI
—

Abstract

In this study, the effect of height of infill wall on shear force of short column of the building was investigated. The effect of the gap ratio between the infill wall and the frame on shear force of the columns was studied considering the building both has no infill wall and has the different ratio of height of infill wall. The floors of the building have been modeled as rigid diaphragm. The dynamic analysis of the buildings has been performed in the direction of the length of the infill wall by using SAP2000 computer program. The results show that the gap between the infill wall and the frame affected the shear force of the columns significantly where the infill walls joined.

Özet

Bu çalışmada, dolgu duvar yüksekliğinin binanın kısa kolon kesme kuvvetine etkisi incelenmiştir. Yapının dolgu duvarsız ve değişik oranlarda dolgu duvar yüksekliği olması durumunda boşluk oranının kesme kuvvetine etkisi araştırılmıştır. Yapıda döşemeler rijit diyafram kabulü yapılarak modellenmiştir. Yapının deprem analizi dolgu duvar uzunluğu yönünde Eşdeğer Deprem Yükü Yöntemi kullanılarak SAP2000 programı ile yapılmıştır. Yapılan analizler sonucunda dolgu duvardaki boşlukların dolgu duvarların bağlandığı kolonların kesme kuvvetini önemli derecede etkilediği görülmüştür.