Journals / Diagnostic and Interventional Radiology / 2015 / Cilt: 21 - Sayı: 2

Percutaneous transluminal balloon angioplasty in stenosis of native hemodialysis arteriovenous fistulas: technical success and analysis of factors affecting postprocedural fistula patency

Pages
160–166
DOI
—

Abstract

PURPOSEWe aimed to determine the predictors of technical success and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVF). METHODS We performed a retrospective analysis of first time PTA in 228 patients (129 men, 99 women; mean age, 56.8±14.6 years). Anatomical (location, length, grade, and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus, AVF age, side, and location) were reviewed. RESULTS A total of 330 stenoses were found in 228 patients. PTA was technically successful in 96.3% of the stenoses (n=319). Clinical success was achieved in 97.2% (n=321). Early dys-function (within six months) was positively correlated with patient age (P < 0.001) and diabetes (P < 0.005). Older age (P < 0.001) and diabetes (P = 0.002) were associated with a lower primary patency rate. Patient age (P < 0.001), presence of diabetes (P = 0.023), length of stenosis (P = 0.003), early recurrence (P = 0.003) and presence of residual stenosis (P = 0.014) were associated with a lower secondary patency rate. CONCLUSION Patency of dysfunctional hemodialysis fistulas can be main-tained safely with continuous follow-up and repeated inter-ventions without shortening the venous segment by surgical revision. Percutaneous approach to hemodialysis access ste-nosis is an alternative to the conventional surgical approach and PTA is an effective treatment method for dysfunctional AVF.