Journals / Retina-Vitreus / 2002 / Cilt: 10 - Sayı: 2
Effects of background diabetic retinopathy on visual field
- Journal
- Retina-Vitreus
- Pages
- 164–169
- DOI
- —
Abstract
Purpose: To demonstrate how the central visual field was affected by different stimulus in patients with background diabetic retinopathy (BDR). Methods: The central 24-2 threshold test with the strategy of fastpac on white background with both white and blue stimulus were done in 28 ( 20 women, 8 men ) patients with the diabetes mellitus without retinopathy, in 15 (10 women, 5 men ) patients with B DR and 26 ( 15 women, 11 men) individuals without any systemic disorders. Results: The averages of mean deviation (MD), pattern standard deviation (PSD), short term fluctuation (SF), corrected pattern standard deviation (CPSD) were found as -5.6 ±3.9 dB, 3.8 ±2.2 dB, 3.1 ±1.3 dB, 2 ±2.3 dB respectively, in the normal individuals. This index values in diabetics without retinopathy were found as -4.3 ±3.8 dB, 3.6 ±1.8 dB, 2.6 ±1.1 dB, 1.9 ±1.9 dB. In diabetics with background retinopathy, those were determined as -5.9 ±4.5 dB, 4.3 ±2.5 dB, 2.9 ±1.3 dB, 2.8 ±2.7 dB. The differences among those indices were not statistically significant (p>0.05). In addition, the differences among the averages of the sums of threshold of both stimulus did not find statistically significant in four quadrants (p>0.05). Conclusion: BDR does not affect the sensitivity of visual field results tested on white background with white and blue stimulus. Ret-vit 2001; 10 :164 -169.
Özet
Amaç: "Background" diabetik retinopatili (BDR) hastalarda, santral görme alanının, değişik uyaranlarla nasıl etkilendiğini saptamak. Gereç ve yöntem: Diabetes mellitus tanısı almış, retinopatisi olmayan 28 hastaya (20 kadın, 8 erkek), BDR1 li 15 hastaya (10 kadın, 5 erkek) ve sistemik hastalığı olmayan 26 kişiye (15 kadın, 11 erkek), santral 24-2 eşik testi, fastpac test stratejisinde beyaz zeminde, beyaz ve mavi uyaranla yapıldı. Bulgular: Normal olgularda, "mean deviation" (MD), "pattern standard deviation" (PSD), "short term fluctuation" (SF), "corrected pattern standard deviation" (CPSD) ortalamaları sırasıyla, -5.6 ±3.9 dB, 3.8 ±2.2 dB, 3.1 ±1.3 dB, 2 ±2.3 dB olarak bulundu. Diabetik, fakat retinopatisi olmayanlarda bu indeks değerleri -4.3 ±3.8 dB, 3.6 ±1.8 dB, 2.6 ±1.1 dB, 1.9 ±1.9 dB olarak bulundu. BDR' si olanlarda ise bunlar -5.9 ±4.5 dB, 4.3 ±2.5 dB, 2.9 ±1.3 dB, 2.8 ±2.7 dB olarak saptandı. Bu global indeksler arasındaki farklar istatistiksel olarak anlamlı değildi (p>0.05). Ayrıca her iki uyaranın dört kadrandaki eşik değer toplamlarının ortalamaları arasındaki fark istatistiksel olarak anlamlı bulunmadı (p>0.05). Sonuç: BDR, beyaz zeminde beyaz ve mavi uyaranla yapılan görme alanı sonuçlarının duyarlılığını etkilememektedir.