Journals / Mühendis ve Makina / 2003 / Cilt: 44 - Sayı: 527

Yer kaynaklı bir ısı pompası sistemindeki toprak ısı değiştiricisi boru uzunluğunun belirlenmesi

Pages
55–61
DOI
—

Abstract

The most important component of ground source heat pump systems, which use earth as a heat source, is the pipes of earth-coupled heat exchangers that are located in the underground. The dimensions of pipes (e.g. diameter, and length) and pipe material selected for settlements of these pipes in the underground are the most significant characteristics of ground source heating and cooling systems, and effect considerably installation cost of heat pump system. In this study, the pipe length of a ground heat exchanger was determined for different heat exchanger configurations (i.e. horizontal, and vertical), pipe materials, and heating and cooling loads. It was concluded that using vertical configuration gives shorter pipe length compared to horizontal configuration.

Özet

Toprağı ısı kaynağı olarak kullanan ısı pompası sistemlerinin en önemli bileşeni, toprak altına döşenen toprak ısı değiştiricilerinin borularıdır. Boruların toprak altına yerleşiminde seçilen boru boyutları (örneğin çap ve uzunluk) ve boru malzemesi toprak kaynaklı ısıtma ve soğutma sistemlerinin en önemli karakteristiğidir ve sistemin maliyetlerini oldukça etkiler. Bu çalışmada, toprak ısı değiştiricisi boru uzunluğu; farklı ısı değiştiricisi şekilleri (yatay ve düşey), boru malzemeleri ve ısıtma ve soğutma kapasiteleri için belirlendi. Düşey toprak ısı değiştiricisi döşendiğinde yatay toprak ısı değiştiricisine göre daha az boru boyu gerektiği saptanmıştır.