Journals / Engineering Sciences / 2010 / Cilt: 5 Sayı: 2

CHARACTERIZATION AND CALIBRATION OF ION-IMPLANTED-SILICON DETECTOR FOR ALPHA PARTICLES MEASUREMENT

ALFA PARÇACIK ÖLÇÜMLERİ İÇİN İYON İMPLANTLI SİLİKON BİR DEDEKTÖRÜN KARAKTERİZASYONU VE KALİBRASYONU

Pages
293–299
Publication Date
2010-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The experimental count results demonstrated that this system can be used in online radon measurements.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Ion implanted - silicon detectors are widely used in the alpha radiation, especially for quantitative analysis in environmental applications.
📊
Key Findings & Data:We have tested the silicon detector and CSA (Charge sensitive amplifier) at the room temperature with test setup, using a Am-241 source with a characteristic energy of 5.485 MeV.
💡
Conclusion & Impact:The experimental count results demonstrated that this system can be used in online radon measurements.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Silikon Dedektör · Yüke Duyarlı Yükselteç · Radon

Abstract

Ion implanted - silicon detectors are widely used in the alpha radiation, especially for quantitative analysis in environmental applications. For quantitative measurements of the alpha radiation, their characterization and electronic calibration is required. We have tested the silicon detector and CSA (Charge sensitive amplifier) at the room temperature with test setup, using a Am-241 source with a characteristic energy of 5.485 MeV. The purpose of these experiments was to calibrate and characterize the response of the radon system to charged particle of the same types and energies as those encountered in soil. To meet these requirements, discriminating with pulse width of 400 ns is adjusted. The experimental count results demonstrated that this system can be used in online radon measurements.

Özet

İyon implantlı silikon dedektörler özellikle çevresel uygulamalardaki nicel analizler için alfa radyasyonu tespitinde kullanılmaktadırlar. Alfa radyasyonunun nicel ölçümleri için, bu tip dedektörlerin karakterizasyonu ve kalibrasyonu mutlaka gerekmektedir. Bu çalışmada, oda sıcaklığında 5.485 MeV'luk karakteristik enerjiye sahip olan Am-241 kaynağı kullanarak silikon dedektör ve CSA (yüke duyarlı amplifikatör) test edilmiştir. Bu deneylerin amacı ise toprak içinde karşılaşılan radyasyon enerjileri ve aynı tipteki parçacıklara karşı dedektörün tepkisini ortaya koymak ve dedektörün kalibrasyonu olmuştur. Bunu sağlamak için ise 400 ns'lik puls genişliği diskriminasyonu ayarlanmıştır. Deneysel sayım sonuçları bu sistemin gerçek zamanlı radon ölçümlerinde kullanılabileceğini göstermiştir.

🔖

Cite This Article

HARMANSAH, C., SAC, M. M., BAYBURT, M. (2010). CHARACTERIZATION AND CALIBRATION OF ION-IMPLANTED-SILICON DETECTOR FOR ALPHA PARTICLES MEASUREMENT. Engineering Sciences, Cilt: 5 Sayı: 2, 293–299. https://ajindex.com/articles/986523

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...