Journals / Acta Orthopaedica et Traumatologica Turcica / 1995 / Cilt: 29 Sayı: 3

Clinical, Radiologic and scintigraphic evaluation of the results of A. Moore and Thompson prostheses in the management of femoral neck fractures

Femur boyun kırıkların tedavisinde A. Moore ve Thompson parsiyel endoprotez uygulama sonuçlarının klinik, radyolojik ve sintigrafik değerlendirilmesi

Pages
192–196
Publication Date
2006-09-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this study, the mean follow-up period was 28.5 months and we have concluded that the clinical, radiologic and scintigraphic results of Thompson type prostheses were better than A.Moore type prostheses

📌 3 Key Takeaways

🎯
Objective & Hypothesis:140 patients had been operated due to femoral neck fractures in the Ortopaedics and Traumatology CIinic Taksim State Hospital during the period of 1985 to 1991 and of this group, 42 patient's results were clinically, radiologically and scintigraphically evaluated.
📊
Key Findings & Data:We evaluated the technical criteria used in the A.Moore type and the Thompson type endoprostheses, and tried to emphasize the significance of Tc-99 bone scanning in assesment of the results of prosthetic replacement.
💡
Conclusion & Impact:In this study, the mean follow-up period was 28.5 months and we have concluded that the clinical, radiologic and scintigraphic results of Thompson type prostheses were better than A.Moore type prostheses
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:femoral neck fractures/therapy · Moore prosthesis · Thompson prosthesis

Abstract

140 patients had been operated due to femoral neck fractures in the Ortopaedics and Traumatology CIinic Taksim State Hospital during the period of 1985 to 1991 and of this group, 42 patient's results were clinically, radiologically and scintigraphically evaluated. We evaluated the technical criteria used in the A.Moore type and the Thompson type endoprostheses, and tried to emphasize the significance of Tc-99 bone scanning in assesment of the results of prosthetic replacement. In this study, the mean follow-up period was 28.5 months and we have concluded that the clinical, radiologic and scintigraphic results of Thompson type prostheses were better than A.Moore type prostheses

Özet

Sağlık Bakanllğı Taksim Hastanesi Ortopedi ve Travmatoloji Kliniği'nde 1985-1991 yılları arasında femur boyun kırığı nedeniyle parsiyel endoprotez (A.Moore ve Thompson) uygulanan 140 hastadan kontrole gelen 42'sinde tedavi sonuçlarını klinik, radyolojik ve sintigrafik olarak inceledik. A.Moore ve Thompson protezlerinin tedavi sonuçlarının uygulama kriterlerini irdeledik ve Teknesyum-99 kemik sintigrafisinin protez sonuçlarının değerlendirilmesindeki önemini belirtmeye çalıştık. Ortalama takip süremizin 28.5 ay olduğu bu çalışmamızda Thompson tipi protezlerde klinik, radyolojik ve sintigrafik sonuçlarının A. Moore tipi protezlere göre daha iyi olduğu sonuca vardık.

🔖

Cite This Article

Kiran, U., Orhan, Z., Parmaksizoglu, A., Ozkaya, U., Yalaman, O., Yazıcı, N. (2006). Clinical, Radiologic and scintigraphic evaluation of the results of A. Moore and Thompson prostheses in the management of femoral neck fractures. Acta Orthopaedica et Traumatologica Turcica, Cilt: 29 Sayı: 3, 192–196. https://ajindex.com/articles/979735

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...