Journals / Journal of Thermal Engineering / 2023 / Cilt: 9 Sayı: 4

Thermal insulation performance curves for exterior walls in heating and cooling seasons

Pages
1053–1069
Publication Date
2023-08-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

TIPCs were validated against published data.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Determination of thermal insulation performance (i.e. optimum insulation thickness, energy saving and payback period) is a tedious and time-consuming task that requires a thorough knowledge in thermal insulation engineering and economics.
📊
Key Findings & Data:The main goal of this paper is to make the determination of insulation performance simple and timesaving by introduc-ing thermal insulation performance curves (TIPCs) from which the insulation performance can easily be found for any climate condition and all economic factors related to energy and insulation.
💡
Conclusion & Impact:TIPCs were validated against published data.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Degree-day · Energy saving · Insulation characteristic curves

Abstract

Determination of thermal insulation performance (i.e. optimum insulation thickness, energy saving and payback period) is a tedious and time-consuming task that requires a thorough knowledge in thermal insulation engineering and economics. The main goal of this paper is to make the determination of insulation performance simple and timesaving by introduc-ing thermal insulation performance curves (TIPCs) from which the insulation performance can easily be found for any climate condition and all economic factors related to energy and insulation. These curves were generated based on a life-cycle cost analysis (LCCA) method. The curves can be easily read based on a single factor, called the f-factor, which comprises the number of degree-day, coefficient of performance, present worth factor, energy cost, and insu-lation cost. With the gain of heating and cooling degree days (i.e. HDD and CDD), TIPCs can be used for both heating and cooling loads. TIPCs cover commonly used insulation materials for building walls with thermal conductivities range from 0.020 to 0.055 W/m K. TIPCs were validated against published data.

🔖

Cite This Article

BATIHA, M. A., RAWADİEH, S., BATIHA, M., AL-MAKHADMEH, L., KAYFECI, M., MARACHLI, F. (2023). Thermal insulation performance curves for exterior walls in heating and cooling seasons. Journal of Thermal Engineering, Cilt: 9 Sayı: 4, 1053–1069. https://ajindex.com/articles/955547

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. International Energy Agency. Key World Energy Statistics. Paris: International Energy Agency; 2017.
  2. Abu-Jdayil B, Mourad AH, Hittini W, Hassan H, Hameedi S. Traditional, state-of-the-art and renewable thermal building insulation materials: An overview. Constr Build Mater 2019;214:709–735. [CrossRef] Kaynakli O. A review of the economical and optimum thermal insulation thickness for building applications. Renew Sustain Energy Rev 2012;16:415–425. [CrossRef] Jelle BP. Traditional, state-of-the-art and future thermal building insulation materials and solutions - Properties, requirements and possibilities. Energy Build 2011;43:2549–2563. [CrossRef] Yu QL, Spiesz P, Brouwers HJH. Development of cement-based lightweight composites - Part 1: Mix design methodology and hardened properties. Cem Concr Compos 2013;44:17–29. [CrossRef]