Determination of the concentrations and elemental compositions of particulate matter in photocopy centers

Fotokopi merkezlerinde partikül madde konsantrasyonlarının ve element kompozisyonlarının belirlenmesi

Pages
178–189
Publication Date
2017-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Mass concentrations and elemental compositions of particulate matter collected was determined for 5 different size fractions (PM>2.5, PM2.5-1.0, PM1.0-0.5, PM0.5-0.25 ve PM<0.25) and the results of this study were evaluated within this context.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, particulate matter sampling was carried out in order to determine the indoor air particle pollution arising from photocopying.
📊
Key Findings & Data:For that purpose, 9 different photocopy centers were selected in Kocaeli.
💡
Conclusion & Impact:Mass concentrations and elemental compositions of particulate matter collected was determined for 5 different size fractions (PM>2.5, PM2.5-1.0, PM1.0-0.5, PM0.5-0.25 ve PM<0.25) and the results of this study were evaluated within this context.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Partikül madde · fotokopi · Sioutas sıralı örnekleyici

Abstract

In this study, particulate matter sampling was carried out in order to determine the indoor air particle pollution arising from photocopying. For that purpose, 9 different photocopy centers were selected in Kocaeli. The samples were collected with using a 5-stage Sioutas Cascade Impactor and the elemental compositions were analysed with ICP-MS analysis technique. Mass concentrations and elemental compositions of particulate matter collected was determined for 5 different size fractions (PM>2.5, PM2.5-1.0, PM1.0-0.5, PM0.5-0.25 ve PM<0.25) and the results of this study were evaluated within this context.

Özet

Bu çalışmada, Kocaeli’nde seçilen 9 farklı fotokopi merkezinde, fotokopi kullanımından kaynaklı iç ortam partikül madde kirliliğinin belirlenmesi amacıyla partikül madde örneklemeleri gerçekleştirilmiştir. Örnekler, 5 aşamalı Sioutas sıralı örnekleyici kullanılarak toplanmış ve element içerikleri ICP-MS analiz tekniği kullanılarak belirlenmiştir. Toplanan partikül maddelerin kütle konsantrasyonları ve element kompozisyonları, 5 farklı boyut aralığı (PM>2.5, PM2.5-1.0, PM1.0-0.5, PM0.5-0.25 ve PM<0.25) için belirlenmiş ve çalışmanın sonuçları bu kapsamda değerlendirilmiştir.

🔖

Cite This Article

ÇANKAYA, S., PEKEY, B. (2017). Determination of the concentrations and elemental compositions of particulate matter in photocopy centers. Sakarya University Journal of Science, Cilt: 21 Sayı: 2, 178–189. https://ajindex.com/articles/942348

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. R. Hetes, M. Moore, C. Northeim, “Office Equipment: Design, Indoor Air Emissions, and Pollution Prevention Opportunities”. U.S.EPA, EPA/600/SR-95/045, 1995
  2. S.K. Brown, “Assessment of Pollutant Emissions from Dry-Process Photocopiers”. Indoor Air, vol. 9, pp. 259-267, 1999
  3. J.H. Byeon, J.-W. Kim, “Particle Emission From Laser Printers With Different Printing Speeds”. Atmos. Environ., vol. 54, pp. 272-276, 2012
  4. H. Jiang, L. Lu, “Measurement of the surface charge of ultrafine particles from laser printers and analysis of their electrostatic force”. Atmos. Environ., vol. 44, pp. 3347-3351, 2010
  5. K.W. Leovic, L.S Sheldon, D.A. Whitaker, R.G. Hetes, J.A. Calcagni, J.N. Baskir, “Measurement of Indoor Air Emissions from Dry-Process Photocopy Machines,” J Air Waste Manage, vol. 46:9, pp. 821-829, 1996
  6. D. Saraga, S. Pateraki, A. Papadopoulos, C. Vasilakos, T. Maggos, “Studying The Indoor Air Quality in Three Non-Residential Environments of Different Use: A Museum, a Printery İndustry and an Office,” Build Environ, vol. 46, pp. 2333-2341, 2011
  7. C.-W. Lee, D.-J. Hsu, “Measurements of fine and ultrafine particles formation in photocopy centers in Taiwan,” Atmos Environ, vol. 41, pp. 6598–6609, 2007
  8. L. Morawska, C. He, G. Johnson, R. Jayaratne, T. Salthammer, H. Wang, E. Uhde, T. Bostrom, R. Modini, G. Ayoko, P. Mcgarry, M. Wensing, “An Investigation into the Characteristics and Formation Mechanisms of Particles Originating from the Operation of Laser Printers,” Environ Sci Technol, vol. 43, pp.1015–1022, 2009
  9. G. Sangiorgi, L. Ferrero, B.S. Ferrini, C.L. Porto, M.G. Perrone, R. Zangrando, A. Gambaro, Z. Lazzati, E Bolzacc, “Indoor airborne particle sources and semi-volatile partitioning effect of outdoorfine PM in offices,” Atmos Environ, vol. 65, pp 205-214, 2013
  10. M. Khatri, D. Bello, A.K. Pal, S. Woskie, T.H. Gasset, P. Demokritou, P. Gaines, “Toxicological effects of PM0.25–2.0 particles collected from a photocopycenter in three human cell lines,” Inhal Toxicol, vol. 25(11), pp. 621–632, 2013
  11. O. Hanninen, I. Brüske-Hohlfeld, M. Loh, T. Stoeger, W. Kreyling, O. Schmid, A. Peters, “Occupational and Consumer Risk Estimates for Nanoparticles Emitted by Laser Printers,” J Nanopart Res, vol. 12, pp. 91–99, 2010
  12. R. Gminski, K. Decker, C. Heinz, A. Seidel, M. Könczöl, E. Goldenberg, B. Grobety, W. Ebner, R. Giere, V. Mersch-Sundermann, “Genotoxic Effects of Three Selected Black TonerPowders and Their Dimethyl Sulfoxid