Journals / Current Research in Dental Sciences / 2021 / Cilt: 31 Sayı: 3

LİTERATÜRDE IN VITRO ELEKTRONİK APEKS BULUCU ÇALIŞMALARINDA KULLANILAN ORTAM ÇEŞİTLERİ: BİR DERLEME

Pages
454–458
Publication Date
2021-07-14
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Keywords: endodontics, root canal therapy, tooth apex.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Kök kanalı tedavisinde uzun vadeli başarı, kök kanal sisteminin en uygun şekilde dezenfeksiyonu, preparasyonu ve doldurulması ile mümkündür.
📊
Key Findings & Data:Çalışma prensibi genel olarak dokular arasındaki empedans farkının tespitine dayanmaktadır.
💡
Conclusion & Impact:Keywords: endodontics, root canal therapy, tooth apex.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:endodonti · kök kanal tedavisi · diş apeksi.

Özet

Kök kanalı tedavisinde uzun vadeli başarı, kök kanal sisteminin en uygun şekilde dezenfeksiyonu, preparasyonu ve doldurulması ile mümkündür. Kanal tedavisinin sonlanacağı yeri belirlemek tedavinin en önemli basamaklarından biridir. Preparasyonun taşkın yapılması post-operatif ağrıyı artırabilirken, kısa kök kanal dolgusu yeterli dezenfeksiyonun yapılamamasına sebep olabilir. Bu aşamada, elektronik apeks bulucular (EAB) yüksek bir doğruluk seviyesinde apikal daralımın yerinin tespit edilmesine yardımcı olmaktadırlar. Çalışma prensibi genel olarak dokular arasındaki empedans farkının tespitine dayanmaktadır. Elektronik apeks bulucu cihazların, hastada kullanılmadan önce doğruluğunun araştırılması başarılı tedaviler açısından önemlidir. Aynı zamanda, apeks bulucuların ölçme başarısını etkileyebilecek kanal içi solüsyonların, ilaçların, enstrümanların in vitro çalışmalarla değerlendirilmesi önemlidir. Piyasada bulunan apeks bulucuların ölçüm doğruluklarını değerlendiren birçok in vitro çalışma yapılmıştır. Bu in vitro çalışmalar gerçekleştirilirken periapikal dokuları taklit edecek elektro-iletken test ortamları gereklidir. Kullanılan test ortamları jelatin, aljinat, agar agar, salin solüsyonu, çiçek süngeridir. Bu derlemenin amacı, literatürdeki in vitro çalışmalarda kullanılan test ortamları hakkında bilgi vermektir. Anahtar kelimeler: endodonti, kök kanal tedavisi, diş apeksi. MEDIA VARIETIES USED IN IN VITRO ELECTRONIC APEX LOCATORS STUDIES IN LITERATURE: A REVİEW SUMMARY Long-term success in root canal treatment is possible with appropriate disinfection, preparation and filling of the root canal system. Determining the ending point of root canal therapy is one of the most important steps of the treatment. While over-preparation can increase the post-operative pain, short root canal filling may cause inadequate disinfection. At this point, electronic apex locators (EAL) help to locate the apical constriction with high accuracy level. The principle of operation is generally based on the detecting the impedance difference between tissues. It is important to investigate the accuracy of electronic apex locators before using them in patients with regard to successful treatments. To evaluate the intra-canal solutions, medicaments, instruments, which may affect the measuring success of apex locators, is important by means of in vitro studies. Many in vitro studies have been done to evaluate the accuracy of apex locators on the market. Electroconductive test environments that mimic periapical tissues are required when performing these in vitro studies. The test media used are gelatin, alginate, agar agar, saline solution, flower sponge. The purpose of this review is to provide information about in vitro test environments used in the literature. Keywords: endodontics, root canal therapy, tooth apex.

🔖

Cite This Article

CUDAL, H., ASLAN, T., ÜSTÜN, Y. (2021). LİTERATÜRDE IN VITRO ELEKTRONİK APEKS BULUCU ÇALIŞMALARINDA KULLANILAN ORTAM ÇEŞİTLERİ: BİR DERLEME. Current Research in Dental Sciences, Cilt: 31 Sayı: 3, 454–458. https://ajindex.com/articles/900917

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Ricucci D. Apical limit of root canal instrumentation and obturation, part 1. Literature review. Int Endod J 1998;31:384-93
  2. Estrela C, Holland R, Estrela CR, Alencar AH, Sousa-Neto MD, Pecora JD. Characterization of successful root canal treatment. Braz Dent J 2014;25:3-11
  3. Ali R, Okechukwu NC, Brunton P, Nattress B. An overview of electronic apex locators: Part 1. Br Dent J 2013;214:155-8
  4. Czerw RJ, Fulkerson MS, Donnelly JC. An in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 1994;20:605-6
  5. Custer LE. Exact methods of locating the apical foramen. J Nat Dent Ass 1918;5:815–9
  6. Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375– 87
  7. Baldi JV, Victorino FR, Bernardes RA, de Moraes IG, Bramante CM, Garcia RB, Bernardinelli N. Influence of embedding media on the assessment of electronic apex locators. J Endod 2007;33:476-9
  8. Ibarrola JL, Chapman BL, Howard JH, Knowles KI, Ludlow MO. Effect of preflaring on Root ZX apex locators. J Endod 1999;25:625-6
  9. Ozsezer E, Inan U, Aydin U. In vivo evaluation of ProPex electronic apex locator. J Endod 2007; 33: 974-7
  10. Ustun Y, Uzun O, Er O, Canakci BC, Topuz O. The effect of residual calcium hydroxide on the accuracy of a contemporary electronic apex locator. Acta Odontol Scand 2015;73:132-6
  11. Stober EK, de Ribot J, Mercade M, Vera J, Bueno R, Roig M, Duran-Sindreu F. Evaluation of the Raypex 5 and the Mini Apex Locator: an in vivo study. J Endod 2011;37:1349-52
  12. Serna-Pena G, Gomes-Azevedo S, Flores-Trevino J, Madla-Cruz E, Rodriguez-Delgado I, Martinez-Gonzalez G. In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi. J Endod 2020;46:158-61
  13. Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod 1996;22:616-8
  14. Meares WA, Steiman HR. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator. J Endod 2002;28:595-8
  15. Abdelsalam N, Hashem N. Impact of Apical Patency on Accuracy of Electronic Apex Locators: In Vitro Study. J Endod 2020;46:509-14
  16. Jadhav GR, Mittal P, Patil V, Kandekar P, Kulkarni A, Shinde S, Syed S, Elahi S. Accuracy of Different Apex Locators in Teeth with Simulated Apical Root Resorption: an In Vitro Study. Folia Med 2018;60:624-31
  17. Abdelsalam N, Hashem N. Impact of Apical Patency on Accuracy of Electronic Apex Locators: In