⚡ TL;DR(Too Long; Didn't Read)

Simulation results demonstrate the NN fault location estimation in percent of line length are in a suitable range.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Nowadays, microgrids have attracted much attention in developed countries.
📊
Key Findings & Data:The acquaintance on fault location in distribution network causes for quick restoration, maintenance and decrease unnecessary power outage period.
💡
Conclusion & Impact:Simulation results demonstrate the NN fault location estimation in percent of line length are in a suitable range.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Fault location · neural network (NN) · multi-layer perceptron (MLP)

Abstract

Nowadays, microgrids have attracted much attention in developed countries. The protection of DC systems, unlike conventional AC systems, is a highly challenging task. The acquaintance on fault location in distribution network causes for quick restoration, maintenance and decrease unnecessary power outage period. Neural Networks (NNs) are among the powerful, reliable approaches and are used in many different engineering applications. Also, Multi-Layer Perceptron (MLP) NNs are used for different estimating problems. This paper presents an accurate protection method for Low-Voltage DC (LVDC) ring-bus microgrid systems based on MLP NN. The aim of the proposed method is precise fault location estimation in microgrids, irrespective of the type and magnitude of fault, current, and the power supply quantity, by instantaneous current monitoring of each segment of the microgrid. Simulation results demonstrate the NN fault location estimation in percent of line length are in a suitable range. The results show that the estimation error is small and is within the permissible range. According to the results, efficiency and accuracy of MLP NN are confirmed. To do so, an LVDC ring-bus microgrid is used that utilizes solid-state bidirectional switches along with master and slave controllers

🔖

Cite This Article

ABDALI, A., MAZLUMI, K., NOROOZIAN, R. (2018). A PRECISE FAULT LOCATION SCHEME FOR LOW-VOLTAGE DC MICROGRIDS SYSTEMS USING MULTI-LAYER PERCEPTRON NEURAL NETWORK. Sigma Journal of Engineering and Natural Sciences, Cilt: 36 Sayı: 3, 821–834. https://ajindex.com/articles/897737

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Abdali, A., Noroozian, R., & Mazlumi, K. (2019). Simultaneous control and protection schemes for DC multi microgrids systems. International Journal of Electrical Power & Energy Systems, 104, 230-245. ‏DOI: 10.1016/j.ijepes.2018.06.054
  2. F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid synchronization for distributed power generation systems,” IEEE Transactions on industrial electronics, vol. 53, no. 5, pp. 1398–1409, 2006
  3. A. Abdali, K. Mazlumi and R. Noroozian, "Fast fault detection and isolation in low-voltage DC microgrids using fuzzy inference system," 2017 5th Iranian Joint Congress on Fuzzy and Intelligent Systems (CFIS), Qazvin, 2017, pp. 172-177. IEEE, DOI: 10.1109/CFIS.2017.8003678
  4. H. Nikkhajoei and R. H. Lasseter, “Distributed generation interface to the certs microgrid,” IEEE Transactions on Power Delivery, vol. 24, no. 3, pp. 1598–1608, 2009
  5. F. Katiraei, R. Iravani, N. Hatziargyriou, and A. Dimeas, “Microgrids management,” IEEE Power and Energy Magazine, vol. 6, no. 3, pp. 54– 65, 2008
  6. R. M. Cuzner and G. Venkataramanan, “The status of dc micro-grid protection,” in Industry Applications Society Annual Meeting, 2008. IAS’08. IEEE, pp. 1–8, IEEE, 2008
  7. D. Salomonsson, L. Soder, and A. Sannino, “Protection of low-voltage dc microgrids,” IEEE Transactions on Power Delivery, vol. 24, no. 3, pp. 1045–1053, 2009
  8. M. Saeedifard, M. Graovac, R. Dias, and R. Iravani, “Dc power systems: Challenges and opportunities,” in IEEE PES General Meeting, pp. 1–7, IEEE, 2010
  9. P. Salonen, P. Nuutinen, P. Peltoniemi, and J. Partanen, “LVDC distribution system protection solutions, implementation and measurements,” in Power Electronics and Applications, 2009. EPE’09. 13th European Conference on, pp. 1–10, IEEE, 2009
  10. T. Ericsen, N. Hingorani, and Y. Khersonsky, “Power electronics and future marine electrical systems,” in Petroleum and Chemical Industry Technical Conference, 2004. Fifty-First Annual Conference 2004, pp. 163–171, IEEE, 2004
  11. J. Ren, S. Venkata, and E. Sortomme, “An accurate synchrophasor based fault location method for emerging distribution systems,” IEEE Transactions on Power Delivery, vol. 29, no. 1, pp. 297–298, 2014
  12. L. Tang and B.-T. Ooi, “Locating and isolating dc faults in multiterminal dc systems,” IEEE transactions on power delivery, vol. 22, no. 3, pp. 1877–1884, 2007
  13. S. Azizi, M. Sanaye-Pasand, M. Abedini, and A. Hasani, “A traveling wave based