Journals / Çukurova Üniversitesi Mühendislik Fakültesi dergisi / 2019 / Cilt: 34 Sayı: 3

Exposure to Volatile Organic Compounds in Photocopy Centers

Fotokopi Merkezlerinde Uçucu Organik Bileşiklere Maruziyet

Pages
155–162
Publication Date
2019-09-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The daily average exposure to TVOC in photocopy centers detected from 15.76-to 129.03 µg/m3.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Photocopiers have been caused indoor air quality problems.
📊
Key Findings & Data:Eighteen different VOCs were detected in photocopy center 2 and concentrations ranged from 0.52 µg/m3 to 35.90 µg/m3.
💡
Conclusion & Impact:The daily average exposure to TVOC in photocopy centers detected from 15.76-to 129.03 µg/m3.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Uçucu organik bileşikler · Hava · İç ortam

Abstract

Photocopiers have been caused indoor air quality problems. Studies conducted in the laboratory in the test chamber have indicated that several volatile organic compounds (VOCs) emitted during photocopier operation of photocopier machines. In this study, area samples from four photocopy centers and two outdoor air samples in Konya were collected in charcoal tubes and analyzed using gas chromatography-mass spectrometry according to the standard method developed by NIOSH. Eighteen different VOCs were detected in photocopy center 2 and concentrations ranged from 0.52 µg/m3 to 35.90 µg/m3. The maximum concentration was determined as 77.59 µg/m3 (toluene, photocopy center 3). The daily average exposure to TVOC in photocopy centers detected from 15.76-to 129.03 µg/m3.

Özet

Fotokopi makineleri iç ortam hava kalite problemlerine yol açabilmektedir. Laboratuar ortamında test odasında yapılan çalışmalar fotokopi makinelerinin fotokopi işlemi süresince çok sayıda uçucu organik bileşiği (UOB) yaydığını göstermiştir. Bu çalışmada dört fotokopi merkezinden ve iki dış hava örneğinden alınan alan numuneleri aktif karbon tüplerinde toplanmış ve gaz kromatografisi-kütle spektrometresi kullanılarak NIOSH tarafından geliştirilen standart metoda göre analiz edilmiştir. Fotokopi merkezi 2’de 0,52-35,90 µg/m3 aralığında 18 farklı uçucu organik bileşik belirlenmiştir. Maksimum konsantrasyon 77,59 µg/m3 olarak (toluen, fotokopi merkezi 3) belirlenmiştir. Fotokopi merkezlerinde toplam uçucu organik bileşik maruziyeti 15,76-129,03 µg/m3.gün aralığında tespit edilmiştir.

🔖

Cite This Article

KARA, G. (2019). Exposure to Volatile Organic Compounds in Photocopy Centers. Çukurova Üniversitesi Mühendislik Fakültesi dergisi, Cilt: 34 Sayı: 3, 155–162. https://ajindex.com/articles/895226

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. US EPA, 1991. Building Air Quality: A Guide for Building Owners and Managers, EPA/400/1-91/033, Washington
  2. Khatri M., Bello D., Pal A., Joel MC., Woskie S., Gassert T., Lan J., Gu AZ., Demokritou P., Gaines P., 2013. Evaluation of Cytotoxic, Genotoxic and Inflammatory Responses of Nanoparticles from Nphotocopiers in Three Human Cell Lines, Part. Fibre Toxicol, 10, 42-64
  3. Martin J., Bello D., Bunker K., Shafer M., Christiani D., Woskie S., Demokritou P., 2015. Occupational Exposure to Nanoparticles at Commercial Photocopy Centers, J Hazard Mater, 298, 351–360
  4. HeC., Morawska L., Taplin L., 2007. Particle Emission Characteristics of Office Printers. Environ Sci Technol, 4, 6039–6045
  5. Kiurski, J.S., Marić, B.B., Oros, I.B., Kecić, V.S., 2017. The Ecodesign Practice in Serbian Printing Industry, J Clean Prod, 149, 1200-1209
  6. Tang T., Hurra J., Gminski R., Mersch-Sundermann V., 2012. Fine and Ultrafine Particles Emitted from Laser Printers as Indoor Air Contaminants in German offices, Environ Sci Pollut Res Int, 19(9), 3840–3849
  7. Kim SY., Kim Y., Byeon JH., Lee DY., Hwang J., 2009. Emission of Submicron Aerosol Particles in Operating a Laser Beam Printer. Int J Precis Eng Manuf, 10(5), 33–36
  8. Destaillats H., Maddalena RL., Singer BC., Hodgson AT., McKone TE., 2008. Indoor Pollutants Emitted by Office Equipment: a Review of Reported Data and Information Needs, Atmos Environ, 42, 1371–1388
  9. Kowalska, J., Szewczyńska, M., Pośniak, M., 2015. Measurements of Chlorinated Volatile Organic Compounds Emitted from Office Printers and Photocopiers, Environ Sci Pollut Res, 22, 5241–5252
  10. Kiurski, JS., Aksentijević, S.M., Mandarić, S.D., 2018. Statistical Approach for Characterization of Photocopying Indoor Pollution, Air Qual Atmos Health, 11, 867-881
  11. Henschel, B.D., Fortann, R.C., Roache, N.F., 2001. Variations in the Emission of Volatile Organic Compounds from the Toner for a Specific Photocopier, J Air Waste Manag Assoc, 51, 708–717
  12. Leovic, K.W., Whitaker, D.A., Northeim, C., Sheldon, L.S., 1996. Measurement of Indoor Air Emissions from Dry-process Photocopy Machines, J Air Waste Manag Assoc, 46, 821-829
  13. Lee, C.W., Hsu, D.J., 2007. Measurements of Fine and Ultrafine Particles Formation in Photocopy Centers in Taiwan, Atmos Environ, 41, 6598-6609
  14. Lee, S.C., Lam, S., Fai. H.K., 2001. Characterization of VOCs, Ozone and PM10 Emissions from Office Equipment in an Environmental Chamber, Build Environ, 36, 837–842
  15. Awadi