Journals / The Ulutas Medical Journal / 2016 / Cilt: 2 - Sayı: 2

Axillary Brachial Plexus Block Application for Reduction of Radius Head Fracture and Elbow Dislocation which Developed after the Trauma in Vertical Wind Tunnels

Pages
126–129
Publication Date
2016-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It is considered that the application of axillary brachial plexus block for reduction in a case of upper extremity dislocation with fracture that happened during a VWT simulation training was safe and effective.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Introduction: To attain and maintain the level of training and skill necessary for the free-fall stage, vertical wind tunnels VWT are commonly used.
📊
Key Findings & Data:A 26-year-old male patient fell on his left side, as he could not maintain his position in the VWT.
💡
Conclusion & Impact:It is considered that the application of axillary brachial plexus block for reduction in a case of upper extremity dislocation with fracture that happened during a VWT simulation training was safe and effective.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Analgesia · axillary block · regional block

Abstract

Introduction: To attain and maintain the level of training and skill necessary for the free-fall stage, vertical wind tunnels VWT are commonly used. Skydiving trials might result in extremity fractures. In order to manage pain, peripheral nerve blocks consisting Axillary Brachial Plexus Block ABPB is a novel technique with shows promising results in this area. Case Presentation: We presented a case on the successful application of an ABPB in the reduction of radius head fracture and elbow dislocation. A 26-year-old male patient fell on his left side, as he could not maintain his position in the VWT. In plain radiography, an oblique fracture line on the left radius head and dislocation on the left elbow were observed. During the examination his Visual Analog Score was identified as 98 mm, and in order for the patient to be able to tolerate the painful procedure, an axillary brachial plexus block was preferred. We were unable to establish in the literature the traumatic injuries that occur in VWTs, as a result of free-fall simulations, or any statistics on such injuries. Conclusion: In emergency rooms, where patient load is heavy and the amount of healthcare personnel is low, peripheral nerve block can be an appropriate choice for the emergency physician before undertaking a painful procedure. It is considered that the application of axillary brachial plexus block for reduction in a case of upper extremity dislocation with fracture that happened during a VWT simulation training was safe and effective.

🔖

Cite This Article

BİLGE, S., AYDİN, A., KAYA, M., CEVİK, E., ERYİLMAZ, M., AYDİN, C. (2016). Axillary Brachial Plexus Block Application for Reduction of Radius Head Fracture and Elbow Dislocation which Developed after the Trauma in Vertical Wind Tunnels. The Ulutas Medical Journal, Cilt: 2 - Sayı: 2, 126–129. https://ajindex.com/articles/844505

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Amit Khurana, CK Ranjan, Decompression chamber runs for screening and training of HALO paratroopers and training of fighter aircrew, Ind J Aerospace Med 52(2), 2008.
  2. Young KW, Kim JS, Cho JH, Kim HS, Cho HK, Lee KT. Paratrooper's ankle fracture: posterior malleolar fracture. Clin Orthop Surg. 2015;7:15-21.
  3. Mautner K, Keel JC. Musculocutaneous nerve injury after simulated freefall in a vertical wind-tunnel: a case report. Arch Phys Med Rehabil. 2007;88:391-3. Hodkinson PD. Acute exposure to altitude. J R Army Med Corps. 2011;157:85-91.
  4. D Dhar, Retrospective Study of Injuries in Military Parachuting MJAFI, Vol. 63, No. 4, 2007
  5. Oong Z., Cooksley T., Holland M., C5-C6 brachial plexus injury sustained as a result of indoor skydiving, retrieved from http://www.acutemedicine.org.uk/wp-content/uploads /2014/12/Case-Reports-Abstract-Book.pdf Koval K, Haidukewych GJ, Service B. Controversies in the Management of Distal Radius Fractures. J Am Acad Orthop Surg. 2014; 22: 566-575.