Journals / The Ulutas Medical Journal / 2019 / Cilt: 5 - Sayı: 1

Comparison of LigaSure and the Conventional Method in Total Thyroidectomy: A Single Surgeon’s Experience and Review of the Literature that LigaSure is not superior to Suture Ligation in Total Thyroidectomy

Pages
77–83
Publication Date
2019-01-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Sutureless thyroid operations with Ligasure can be safely performed without the presence of higher complication risks but does not reduce surgical time or hospitalization.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background: The objective of this study was to compare the results of the LigaSure® Precise vessel sealing system and conventional suture ligation CSL for total thyroidectomy in terms of complication rates, hospitalization, and surgical time.
📊
Key Findings & Data:Materials and Methods: This non-randomized retrospective review included 118 consecutive patients.
💡
Conclusion & Impact:Conclusion: Sutureless thyroid operations with Ligasure can be safely performed without the presence of higher complication risks but does not reduce surgical time or hospitalization.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:LigaSure · conventional suture ligation · complication

Abstract

Background: The objective of this study was to compare the results of the LigaSure® Precise vessel sealing system and conventional suture ligation CSL for total thyroidectomy in terms of complication rates, hospitalization, and surgical time. Materials and Methods: This non-randomized retrospective review included 118 consecutive patients. All patients with nodular or multinodular goiter underwent total thyroidectomy by a single surgeon. The patients were divided into two subgroups: CSL was used as the conventional method together with monopolar and bipolar cautery group 1 , and LigaSure® Precise L was used in group 2 as a sealing system for all surrounding tissues of the thyroid gland. Results: No statistically significant differences were found between the two techniques with respect to age, sex, surgical time, hospitalization, and postoperative complications p>0.05 . Conclusion: Sutureless thyroid operations with Ligasure can be safely performed without the presence of higher complication risks but does not reduce surgical time or hospitalization.

🔖

Cite This Article

DEMİRAL, G., AKSOY, F. (2019). Comparison of LigaSure and the Conventional Method in Total Thyroidectomy: A Single Surgeon’s Experience and Review of the Literature that LigaSure is not superior to Suture Ligation in Total Thyroidectomy. The Ulutas Medical Journal, Cilt: 5 - Sayı: 1, 77–83. https://ajindex.com/articles/844441

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Lamberton GR, Hsi RS, Jin DH, Lindler TU, JellisonFC, Baldwin DD. Prospective comparison of four laparoscopic vessel ligation devices. J Endourol. 2008
  2. 2312 2.Ding Z, Wable G, Rane A. Use of LigaSure bipolar diathermy system in vaginal hysterectomy. J Obstet Gynaecol 2005
  3. 51 3. Levy B, Emery L. Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy. Obstet Gynecol 2003
  4. 51 4.Person BI, Vivas DA, Ruiz D, Talcott M, Coad JE, Wexner SD. Comparison of four energy-based vascular sealing and cutting instruments: A porcine model. Surg Endosc 2008
  5. 8 5.Rifaat M, Saber A, Hokkam EN. Total Versus Subtotal Thyroidectomy for Benign Multinodular Goiter: Outcome and Complications. J Curr Surg 2014
  6. 5 6.Kiriakopoulos A, Dimitrios T. Use of a diathermy system in thyroid surgery. Arch Surg 2004
  7. 1000 7.Challa. S, Sushama S. Sutureless thyroidectomy vasucular control using bipolar electrothermal cautery. J Evol Med Dent Sciences 2012
  8. 6 8.Musholt TJ. Total thyroidectomy for multinodular goiter. Chirurg 2010
  9. 6 9.Aljuraibi W, Ahmed MR, Saber A. Use of Ligasure Sealing Versus Conventional Suture Ligation in Thyroidectomy Journal of Surgery 2016
  10. 8 10.Bove A, Bongarzoni G, Palone G, Di Renzo R, Di Nicola M, Corradetti L, et al. Comparative study of an electrothermal bipolar vessel sealing system (LigaSure(R)), a harmonic curved shears (Harmonic Focus), and traditional technique in total thyroidectomy. Am Surg 2010
  11. E94–6 11.Garas G, Okabayashi K, Ashrafian H, Shetty K, Palazzo F, Tolley N, et al. Which hemostatic device in thyroid surgery? a network metaanalysis of surgical technologies. Thyroid 2013
  12. 1138–50 12.Kirdak T, Korun N, Ozguc H. Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 2005
  13. 771–4 13.Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinccag A, et al. The use of LigaSure in patients with hyperthyroidism. Langenbeck’s Archives of Surgery/ Deutsche Gesellschaft fur Chirurgie 2006
  14. 575–9 14.Yao HS, Wang Q, Wang WJ, Ruan CP. Prospective clinical trials of thyroidectomy with LigaSure vs conventional vessel ligation: a systematic review and metaanalysis. Arch Surg 2009
  15. 1167–74 15.Petrakis IE, Kogerakis NE, Lasithiotakis KG, Vrachassotakis N, Chalkiadakis GE. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease. Head Neck 2004
  16. 9 16.Hayward NJ, Grods