Journals / Teknik Dergi / 2021 / Cilt: 32 - Sayı: 1

Trend Analysis of Observed Standart Duration Maximum Precipitation for Istanbul

İstanbul İçin Standart Süreli Gözlenen En Büyük Yağışların Eğilimleri

Pages
10495–10514
Publication Date
2021-01-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As an example, relative difference between first and second half is 30% 5 hour standart duration and 2 years frequecy maximum precipitation for Sarıyer MGI and Q500 design flood discarge increased 60% Bekar Creek in Sarıyer.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Climate variability and change effects each parameter of hydrological cycle.
📊
Key Findings & Data:In this study, trend analysis of standart duration maximum precipitation was performed for 7 meteorological station equipped with pluviograph and located in İstanbul and around.
💡
Conclusion & Impact:As an example, relative difference between first and second half is 30% 5 hour standart duration and 2 years frequecy maximum precipitation for Sarıyer MGI and Q500 design flood discarge increased 60% Bekar Creek in Sarıyer.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Eğilim · Yağış şiddet süre tekerrür eğrisi · maksimum yağışlar

Abstract

Climate variability and change effects each parameter of hydrological cycle. Intensity, duration and frequency of precipitation is the basic information used in the design of bridges, culverts, city storm drainages. In this study, trend analysis of standart duration maximum precipitation was performed for 7 meteorological station equipped with pluviograph and located in İstanbul and around. Data series were divided two equal periods and precipitaion intensity-duration and frequency curves were developed. Except for Kartal MGI, significant increase trend were detected in 6 stations (Sarıyer, Kumköy, Florya, Çorlu, Göztepe ve Şile). As an example, relative difference between first and second half is 30% 5 hour standart duration and 2 years frequecy maximum precipitation for Sarıyer MGI and Q500 design flood discarge increased 60% Bekar Creek in Sarıyer.

Özet

İklim değişkenliği ve değişimi, hidrolojik çevrimin her bir parametresini etkilemektedir. Yağışların şiddet, süre ve tekerrürleri köprüler, menfezler, şehir yağmursuyu drenajlarının tasarımında kullanılan temel bilgidir. Bu çalışmada İstanbul ve civarındaki 7 adet plüviograflı MGİ’de ölçülen standart süreli maksimum yağışların eğilim analizleri yapılmıştır. Veri serileri, iki eşit döneme bölünerek yağış şiddet tekerrür eğrileri oluşturulmuştur. Kartal MGİ haricinde 6 istasyonda (Sarıyer, Kumköy, Florya, Çorlu, Göztepe ve Şile) belirgin artış eğilimleri belirlenmiştir. Bir örnek olarak, Sarıyer meteoroloji istasyonunun 5 saatlik standart süreli 2 yıl tekerrürlü maksimum yağışları ilk dönem ve ikinci dönem hesaplanan bağıl farkları %30 ve Sarıyer’de bulunan Bekar deresinde Q500 taşkın debisindeki %60 artış şeklindedir.

🔖

Cite This Article

ŞEN, K., AKSU, H. (2021). Trend Analysis of Observed Standart Duration Maximum Precipitation for Istanbul. Teknik Dergi, Cilt: 32 - Sayı: 1, 10495–10514. https://ajindex.com/articles/83730

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Trenberth, K. E., (2011) Changes in precipitation with climate change. Clim Res 47, 123
  2. Intergovernmental Panel on Climate Change (IPCC). (2007). “Climate change 2007: Physical science basis.” Contribution of Working Group I to the 4th Assessment Rep. of the Intergovernmental Panel on Climate Change, S. Solomon, et al., eds., Cambridge University Press, New York
  3. Intergovernmental Panel on Climate Change (IPCC). (2008). “Climate change and water.” Technical Paper of the Intergovernmental Panel on Climate Change, B. C. Bates, et al., eds., IPCC Secretariat, Geneva, Switzerland
  4. Kundzewicz, Z. W., et al. (2005). “Summer floods in Central Europe— Climate change track” Nat. Hazards, 36(1–2), 165–189
  5. Collins, M. J. (2009). “Evidence for changing flood risk in New England since the late 20th century.” J. Am. Water Resour. Assoc., 45(2), 279–290
  6. Cheng, L. & AghaKouchak, A., (2014). Nonstationary Precipitation Intensity-Duration-Frequency Curves for Infrastructure Design in a Changing Climate. Nature: Scientific Reports, Volume 4, p. 7093
  7. Bernard, M. M., (1932). Formulas for Rainfall Intensities of Long Duration, 96: 592-624
  8. Hershfield, D.M., (1961) Rainfall frequency atlas of the United States for durations from 30 minutes to 24 hours and return periods from 1 to 100 Years, US Weather Bureau Technical Paper 40, Washington DC
  9. Chow, V.T., (1964) Statistical and probability analysis of hydrologic data. Part I: frequency analysis, Handbook of Applied Hydrology. Sec. 8-I, 8.1-8.42, Mc Graw Hill, New York
  10. Miller J.F., Frederick R.H., Tracey R.J. & Nerc. (1973) Precipitation frequency analysis of the Western US, NOAA Atlas, National Weather Service, US Department of Commerce, Siver Spring, MD
  11. Koutsoyiannis D., Kozonis D. & Manetas A. A (1998) Mathematical framework for studying rainfal IDF relationships. J Hydrol, 206, 118–135
  12. Linsley R.K. Jr., Kohler M.A. & Paulus J.L.H. (1975) Hydrology for Engineers, 2nd ed. Tokyo: Mc Graw Hill
  13. Chen C.I., (1983) Rainfall intensity–duration–frequency formulas. J Hydrol Eng, 109, (12), 1603–1621
  14. Burn, D. H., Mansour, R., Zhang, K., and Whitfield, P. H. (2011). “Trends and variability in extreme rainfall events in British Columbia.” Can. Water Resour. J., 36(1), 67–82
  15. Fujibe, F., Yamazaki, N., Katsuyama, M., and Kobayashi, K. (2005). “The increasing trend of intense precipitation in Japan based on four-hourly data for a hundred years.” SOLA, 1(2005), 41–44. [1