Journals / International Journal of Energy Applications and Technologies / 2017 / Cilt: 4 - Sayı: 4

1P3S HIGH FREQUENCY TRANSFORMER BASED DUAL-ACTIVE BRIDGE DC-DC CONVERTER

Pages
174–181
Publication Date
2017-12-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The performance of the proposed system is verified with various case studies.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The dual active bridge DC-DC converter topology gains developing application area in renewable energy systems, electric vehicles, power quality devices etc. due to its structural and functional advantages.
📊
Key Findings & Data:In this paper, a new dual active bridge (DAB) based DC-DC converter equipped with an isolated high frequency transformer with 1 primary / 3 secondary windings is proposed which is composed of three voltage source converter (VSC) in the secondary side and a voltage source converter in the primary side.
💡
Conclusion & Impact:The performance of the proposed system is verified with various case studies.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Dual active bridge · H bridge · DC-DC converter

Abstract

The dual active bridge DC-DC converter topology gains developing application area in renewable energy systems, electric vehicles, power quality devices etc. due to its structural and functional advantages. In this paper, a new dual active bridge (DAB) based DC-DC converter equipped with an isolated high frequency transformer with 1 primary / 3 secondary windings is proposed which is composed of three voltage source converter (VSC) in the secondary side and a voltage source converter in the primary side. Each voltage source converters have own dc links. The single phase shift modulation (SPS) method that is the commonly used control method in high power transfer applications is used for each voltage source converters independently to achieve bidirectional power flow of DC-DC converter. The phase shift modulation is implemented by PI controller. The power flow between the dc-links are provided by VSC’s own phase shift angles. Moreover extended phase shift (EPS) modulation and dual phase shift (DPS) modulation is also implemented to the system to control the power flow. Performance comparison of modulation methods is also done in the study. To validate the proposed system, a simulation model has been developed for 10 kVA rating using MATLAB/Simulink. The performance of the proposed system is verified with various case studies.

🔖

Cite This Article

SAVRUN, M. M., KOROGLU, T., TAN, A., CUMA, M. U., BAYİNDİR, K. C., TUMAY, M. (2017). 1P3S HIGH FREQUENCY TRANSFORMER BASED DUAL-ACTIVE BRIDGE DC-DC CONVERTER. International Journal of Energy Applications and Technologies, Cilt: 4 - Sayı: 4, 174–181. https://ajindex.com/articles/832770

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Karshenas, H.R., Daneshpajooh, H., Safaee, A., Jain P., Bakhshai, A. “bidirectional dc-dc converters for energy storage systems”, Chapter 8 in Energy Storage in the Emerging Era of Smart Grids, Edited by Prof. Rosario Carbone, 2011
  2. Zhao, C., Round, S.D., Kolar, J.W., 2008, “An isolated three-port bidirectional dc-dc converter with decoupled power flow management”, IEEE Transactions on Power Electronics, 23(5), 2443-2453
  3. Ardi, H., Ahrabi, R.R., Ravadanegh, S.N., 2014, “Non-isolated bidirectional DC-DC converter analysis and implementation”, IET Power Electronics, 7(12), 3033-3044
  4. Lin, C.C., Yang, L.S., Wu, G.W., 2012, “Study of a non-isolated bidirectional DC-DC converter”, IET Power Electronics, 6(1), 30-37
  5. Tytelmaier, K., Husev, O., Veligorskyi, O., and Yershov, R., 2016, “A review of non-isolated bidirectional dc-dc converters for energy storage systems”, International Young Scientists Forum on Applied Physics and Engineering
  6. Aggeler, D., Biela, J., Inoue, S., Akagi, H., 2007, “Bi-directional isolated dc-dc converter for next-generation power distribution – comparispn of converters using Si and SiC Devices”, Power Conversion Conference. 510-517
  7. Zhao, B., Song, Q., Liu, W., Sun, Y., 2014, “Overview of dual-active-bridge isolated bidirectional DC-DC converter for high-frequency-link power-conversion system”, IEEE Transactions on Power Electronics, 29(8), 4091-4106
  8. Venkatesa, V., 1989, “Current mode controlled bidirectional flyback converter”, Power Electronics Specialists Conference, 2, 835-842
  9. Chung, H.S.H., Cheung W.L., Tang, K.S., 2004, “A ZCS bidirectional flyback DC/DC converter”, IEEE Transactions on Power Electronics, 19(6), 1426-1434
  10. Zhang, F., Yan, Y., 2009, “Novel forward-flyback hybrid bidirectional DC-DC converter”, IEEE Transactions on Industrial Electronics, 56(5), 1578-1584
  11. Huber, L., Jovanovic, M.M., 1999, “Forward-flyback converter with current-doubler rectifier: analysis, design, and evaluation results”, IEEE Transactions on Power Electronics, 14(1), 184-192
  12. Aboulnaga, A.A., Emadi, A., 2004, “Performance evaluation of the isolated bidirectional cuk converter with integrated magnetics”, Annual IEEE Power Electronics Specialists Conference, 1557-1562
  13. Li, H., Peng, F.Z., Lawler, J.S., 2003, “A natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices”, IEEE