Journals / Trakya Üniversitesi Mühendislik Bilimleri Dergisi / 2019 / Cilt: 20 - Sayı: 1

BEHAVIOR OF REINFORCED CONCRETE COLUMNS OF BUILDINGS EXPOSED TO A REAL FIRE, PART I

YAPILARDA BETONARME KOLONLARIN TABİİ YANGINLARDA DAVRANIŞ DURUMLARI, BÖLÜM I

Pages
1–21
Publication Date
2019-07-23
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results show that the prolonged heating of the reinforcing steel may cause to failure in the cooling phase of the fire.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Structural fire design is concerned mainly with the avoidance of structural failure or damage so that the fires are to be controlled at an initial stage.
📊
Key Findings & Data:The present paper is aimed at investigating the structural behavior in bending of reinforced concrete columns RFC in an enclosure exposed to real ventilation controlled fires, i.e. fires with a heating and a cooling phase and presents methods for determining the fire resistance of RFCs exposed to a real fire.
💡
Conclusion & Impact:The results show that the prolonged heating of the reinforcing steel may cause to failure in the cooling phase of the fire.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Yangın güvenliği · betonarme yapı kolonları · yangın dayanımı

Abstract

Structural fire design is concerned mainly with the avoidance of structural failure or damage so that the fires are to be controlled at an initial stage. The present paper is aimed at investigating the structural behavior in bending of reinforced concrete columns RFC in an enclosure exposed to real ventilation controlled fires, i.e. fires with a heating and a cooling phase and presents methods for determining the fire resistance of RFCs exposed to a real fire. The results show that the prolonged heating of the reinforcing steel may cause to failure in the cooling phase of the fire. Beside in a separte research work boundary fire loads of reinforced concrete columns for an enclosure are determined beyond which no failure can be expected or fire resistance is much greater than ISO834 in case of a real fire (s. Ref. Part II).

Özet

Yapılar üzerine olan yangın tasarımı esas olarak, yapı elemanın göçmesini ve zarar görmesini önleyerek yapının başlangıç fazında denetim altında tutulmasını sağlamaktır. Sunulan bu çalışma, betonarme kolonların ventilasyon denetimli tabii bir yangın etkimesi durumunda, örneğin ısınma ve soğuma fazlarını içeren bir yangın gelişimi içim, II. Mertebe teorisini kullanarak, yangın davranışlarını ve dayanımlarını belirlemek olacaktır. Araştırma sonuçları beton donatılarında maksimum sıcaklığın soğuma fazının başlamasından sonra, (hatta saatler sonra) meydana gelebileceğini ve bu durumun da yapı elemanında gecikmiş bir göçmeye neden olabileceğini göstermiştir. Donatının uzun süreli ısınması yangının soğuma fazında yapı elemanının göçmesini sağlamaktadır. Bu nedenle kapalı bir hacimde betonarme kolonların sınır yangın yükleri Bölüm II'de saptanmış olup bu sınırın dışında kalan yangınlarda, yapı elemanlarının yangın direnci ISO834 yangınına göre daha büyük olmakta ve hatta bir göçme riski içermemektedir.

🔖

Cite This Article

Haksever, A., HAKSEVER, A. (2019). BEHAVIOR OF REINFORCED CONCRETE COLUMNS OF BUILDINGS EXPOSED TO A REAL FIRE, PART I. Trakya Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 20 - Sayı: 1, 1–21. https://ajindex.com/articles/807388

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Arnault, P. et al.: "Rapport experimental sur les essais avec des feux naturels executes dans la petite installation. Maizieres-les-Metz, Juin 1973
  2. Anderberg, Y., Thelandersson, E. Stress and deformation characteristics of Concrete at high temperatures. Bulletin 54. Div. of Const. Mechanics and Concrete Construction. Lund Inst. Of Technology, Lund, 1976
  3. Bechtold, R. Ehlert, K. P., Wesche, J. Brandver-suche Lehrte. Bau und Wohnforschung; Schriften-reihe des Bundesministers für Raumordnung, Bau-wesen und Städtebau Nr. 04.037, Bonn-Bad Godes-berg, 1978
  4. Bechtold, R.: Zur thermischen Beanspruchung von Auβenstützen im Brandfall. Schriftenreihe des Instituts für Baustoffkunde und Stahlbetonbau der Technischen Universität Braunschweig, Heft 37, 1977
  5. Bizri, H. Structural capacity of reinforced cobcrete columns subjected to fire induced thermal gradients. Rep. No.: UC SESM 73-1. Ubi. Calif., Berkeley, Calif., 1973
  6. Butcher, E.G., et al.: "Comparison between furna(:C tests and experimental fires". Her Majesty' s Stationary Office, Symposium No. 2, London, 1967
  7. Butcher, F. G. Bedford, G. K., Ferdell, P. I.: Further experiments on temperatures reached by steel in building fires. Contribution in symposium Behavior of structural steel in fire. Her Majesty’s Stationary Office, London, 1968
  8. Böhm, B. Fully developed polyethylen and wood compartment fires with application tp structural design. Technical University of Denmark, 1977 9. Christopher D.Eamoni, Elin Jensen,: Reliability analysis of reinforced concrete columns exposed to fire. Fire Safety Journal, Volume 62, Part C, November 2013, Pages 221-229 10. CEB (Comité Euro-International du Beton): “Design of concrete structures of fire resistance” Paris., 1983
  9. DIN 4102.: Brandverhalten von Baustoffen und Bauteilen (Fire behavior of building materials and structural members) Teile (Parts) 1-3, Teile (Parts) 5-7, and Teil (Part) 4., DIN Deutsches Institut für Normung E.V., Beuth Verlag, Berlin, (1981
  10. DIN V18230 – Baulicher Brandschutz im Indus-triebau. (Fire safety in industrial buildings) Beuth Verlag, Berlin, (1989)
  11. DIN 4102.: Brandverhalten von Baustoffen und Bauteilen (Fire behavior of building materials and structural elements) Teile (Parts) 1-3, Teile (Parts) -75, and Teil (Part) 4., DIN Deutsches Institut für Normung E.V., Beuth Verlag, Berlin, (1981
  12. ECCS (European convention for constructional Steelwork), Technical Committee 3.Fire safety of steel structures. Part 1