Journals / Journal of the Turkish Chemical Society Section A: Chemistry / 2019 / Cilt: 6 - Sayı: 2

Novel probes for selective fluorometric sensing of Fe(II) and Fe(III) based on BODIPY dyes

Pages
207–216
Publication Date
2019-06-15
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The limit of detection (LOD) have been calculated to be for the BODIPY 2, 14.61 (Fe2+), 1.22 (Fe3+) and for BODIPY 3, 1.16 (Fe2+) and 1.06 (Fe3+).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Two novel boron-dipyrromethene (BODIPY) based fluorescence turn-off sensors, which demonstrate high selectivity and sensitivity toward Fe2+ and Fe3+ ions have been reported.
📊
Key Findings & Data:A simple and high yielded synthesis of fluorescent BODIPY derivatives with malonyl unit for sensitization have been described.
💡
Conclusion & Impact:The limit of detection (LOD) have been calculated to be for the BODIPY 2, 14.61 (Fe2+), 1.22 (Fe3+) and for BODIPY 3, 1.16 (Fe2+) and 1.06 (Fe3+).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Borondipyrromethenes · UV-Vis spectroscopy · fluorescence

Abstract

Two novel boron-dipyrromethene (BODIPY) based fluorescence turn-off sensors, which demonstrate high selectivity and sensitivity toward Fe2+ and Fe3+ ions have been reported. A simple and high yielded synthesis of fluorescent BODIPY derivatives with malonyl unit for sensitization have been described. This approach provides quick, high yielded and low-cost preparation of probes. The two sensors have been comprised of combination of one and two BODIPY fluorophore and a malonyl unit, substituted on meso position of BODIPYs. Synthesized BODIPY derivatives have been characterized via elemental analyses, mass spectrometry, 1H and 13C spectroscopy and their photophyisical properties were investigated by UV- Vis absorption and fluorescence emission spectroscopy. The synthesized sensors (2, 3) have been used as a fluorescent probe towards the selective and sensitive detection of biologically important Fe2+ and Fe3+ ions in tetrahydrofuran by fluorescence spectroscopy. The limit of detection (LOD) have been calculated to be for the BODIPY 2, 14.61 (Fe2+), 1.22 (Fe3+) and for BODIPY 3, 1.16 (Fe2+) and 1.06 (Fe3+).

🔖

Cite This Article

ŞENKUYTU, E., OKUTAN, E. (2019). Novel probes for selective fluorometric sensing of Fe(II) and Fe(III) based on BODIPY dyes. Journal of the Turkish Chemical Society Section A: Chemistry, Cilt: 6 - Sayı: 2, 207–216. https://ajindex.com/articles/780055

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Hua C-j, Zheng H, Zhang K, Xin M, Gao J-r, Li Y-j. A novel turn off fluorescent sensor for Fe (III) and pH environment based on coumarin derivatives: the fluorescence characteristics and theoretical study. Tetrahedron. 2016;72(51):8365-72
  2. Chen F, Hou F, Huang L, Cheng J, Liu H, Xi P, et al. Development of a novel fluorescent probe for copper ion in near aqueous media. Dyes and Pigments. 2013;98(1):146-52
  3. Wu X, Xu B, Tong H, Wang L. Phosphonate-functionalized polyfluorene film sensors for sensitive detection of iron (III) in both organic and aqueous media. Macromolecules. 2010;43(21):8917-23
  4. Atkinson A, Winge DR. Metal acquisition and availability in the mitochondria. Chemical reviews. 2009;109(10):4708-21
  5. Brugnara C. Iron deficiency and erythropoiesis: new diagnostic approaches. Clinical chemistry. 2003;49(10):1573-8
  6. Zhang X-B, Cheng G, Zhang W-J, Shen G-L, Yu R-Q. A fluorescent chemical sensor for Fe3+ based on blocking of intramolecular proton transfer of a quinazolinone derivative. Talanta. 2007;71(1):171-7
  7. Hirayama T, Nagasawa H. Chemical tools for detecting Fe ions. Journal of clinical biochemistry and nutrition. Journal of clinical biochemistry and nutrition. 2017; 60(1): 39-48
  8. McRae R, Bagchi P, Sumalekshmy S, Fahrni CJ. In situ imaging of metals in cells and tissues. Chemical Reviews. 2009;109(10):4780-827
  9. Chen W-d, Gong W-t, Ye Z-q, Lin Y, Ning G-l. FRET-based ratiometric fluorescent probes for selective Fe 3+ sensing and their applications in mitochondria. Dalton Transactions. 2013;42(28):10093-6
  10. Yang Z, She M, Yin B, Cui J, Zhang Y, Sun W, et al. Three Rhodamine-based “off–on” Chemosensors with high selectivity and sensitivity for Fe3+ imaging in living cells. The Journal of organic chemistry. 2011;77(2):1143-7
  11. Liu M, Hu M, Jiang Q, Lu Z, Huang Y, Tan Y, et al. A novel coumarin derivative as a sensitive probe for tracing intracellular pH changes. RSC Advances. 2015;5(21):15778-83
  12. Zhu X, Zhang Z, Xue Z, Huang C, Shan Y, Liu C, Wang T, et al. Understanding the selective detection of Fe3+ based on graphene quantum dots as fluorescent probes: the K sp of a metal hydroxide-assisted mechanism. Analytical chemistry. 2017; 89(22): 12054-12058
  13. Qin W, Dou W, Leen V, Dehaen W, Van der Auweraer M, Boens N. A ratiometric, fluorescent BODIPY-based probe for transition and heavy metal ions. RSC Advances. 2016;6(10):7806-16
  14. Boens N, Leen V, Dehaen W. Fluorescent indicators based on BODIPY. Chemical Soc