Objective & Hypothesis:In this study, a risk assessment was performed by Fine-Kinney method in various units of an official institutional laboratory.
📊
Key Findings & Data:For this purpose, feasibility of the laboratory determinated, devices and areas with high risk priority were identified.
💡
Conclusion & Impact:After these precautions, "risk acceptable" values are obtained by carrying out risk preventive activities in regions with the highest risk.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Fine Kinney Method · risk analysis

Abstract

In this study, a risk assessment was performed by Fine-Kinney method in various units of an official institutional laboratory. For this purpose, feasibility of the laboratory determinated, devices and areas with high risk priority were identified. In hazardous areas, High-risk materials such as store chemical material, spare part production, molding and pressing, rubber production and shredding, plastic breaking, deburring, cutting and packaging, plastic injection molding machines used. The risks identified in these units can be stated as follows; injury by exposure to chemical materials, diarthrosis and spinal cord injury, limb loss, hearing loss, etc. In these units, the risk assessment was carried out by the Fine Kinney method and necessary precautions were taken and necessary arrangements were made. These measures are applying the control protocol for routine execution of the process, training of personnel for each unit according to ISG rules and giving training seminars at regular intervals, protective clothing and equipment used during operation, regular maintenance and repairs of units. After these precautions, "risk acceptable" values are obtained by carrying out risk preventive activities in regions with the highest risk.

🔖

Cite This Article

YALÇIN, Z. G., DAĞ, M., AYDOĞMUŞ, E. (2018). Risk Analysis by Fine Kinney Method in a Laboratory. Journal of Physical Chemistry and Functional Materials, Cilt: 1 - Sayı: 1, 57–62. https://ajindex.com/articles/778344

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Özkılıç, Ö. (2005). İş Sağlığı ve Güvenliği Yönetim Sistemleri ve Risk Değerlendirme Metodolojileri, TISK, Ankara, Mart
  2. Cavkaytar, Ö., Soyer, Ö., U., Şekerel, B., E., Türkiye’de hava kirliliğinden kaynaklanan sağlık sorunları, Hava Kirliliği Araştırmaları Dergisi, 2(10-111), 2013 [3] http://www.eren-enerji.com.tr/tr/kurumsal/eren-enerji/zetes-1 Son Erişim: 18.08.2018 [4] Erzurumluoğlu, K., Köksal, K., N., Gerek, İ., H., İnşaat sektöründe Fine Kinney Metodu kullanılarak risk analizi yapılması, TMMOB İnşaat Mühendisleri Odası Bildiriler Kitabı, [5] Birgören, B., Fine Kinney risk analizi yönteminde risk analizi yönteminde risk faktörlerinin hesaplama zorlukları ve çözüm önerileri, Uluslararası Mühendislik Araştırma ve Geliştirme Dergisi, January, 2017
  3. Özfırat, M., K., Yetkin, M., E., Şimşir, F., Kahraman, B., Uzunayak üretimindeki mevcut tehlike kaynaklarının iş güvenliği açısından değerlendirilmesi, Madencilik, March, 2016. [7] http://www.nurdogan.net/finekinney_dosyalar/Fine_Kinney_Parametre_ve_Ornek.pdf Son Erişim: 18.08.2017 [8] Kokangü,l A., Polat, U., and Dağsuyu, C., A new approximation for risk assessment using the AHP and Fine Kinney methodologies, Journal Safety Science, 91(24-32), 2017.