Journals / European Annals of Dental Sciences / 2020 / Cilt: 47 - Sayı: 1-3

Repeatability of the Points Used in Posteroanterior Radiography Measurements

POSTEROANTERİOR RADYOGRAFİ ÖLÇÜMLERİNDE KULLANILAN NOKTALARIN TEKRARLANABİLİRLİĞİ

Pages
75–80
Publication Date
2020-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

X-rays were measured with Dolphin 3D cephalometric analysis program at Ankara University Faculty of Dentistry, and the repeatability of the 22 points de-termined on the films was tested by 3 researchers.Results: According to the results of the study, skeletal points are more reliable than dental points.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: The aim of this study is to determine the repeatability of anatomical and dental points used in posteroanterior radiographs with a computer program.Materials and method: X-rays used in the study were taken from the Kirikkale University, Department of Dentistry.
📊
Key Findings & Data:X-rays were measured with Dolphin 3D cephalometric analysis program at Ankara University Faculty of Dentistry, and the repeatability of the 22 points de-termined on the films was tested by 3 researchers.Results: According to the results of the study, skeletal points are more reliable than dental points.
💡
Conclusion & Impact:Conclusion: In the study, two planes were also evaluated and unexpectedly, it is more reli-able in the occlusal plane compared to the midsagittal plane.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:posteroanterior radyografi · oklüzal düzlem · sefalometrik analiz

Abstract

Aim: The aim of this study is to determine the repeatability of anatomical and dental points used in posteroanterior radiographs with a computer program.Materials and method: X-rays used in the study were taken from the Kirikkale University, Department of Dentistry. X-rays were measured with Dolphin 3D cephalometric analysis program at Ankara University Faculty of Dentistry, and the repeatability of the 22 points de-termined on the films was tested by 3 researchers.Results: According to the results of the study, skeletal points are more reliable than dental points. The least reliable skeletal point is the zygomatico-frontal suture, while the mandibu-lar canine is the most reliable dental point. Conclusion: In the study, two planes were also evaluated and unexpectedly, it is more reli-able in the occlusal plane compared to the midsagittal plane.

Özet

Amaç: Bu çalışmanın amacı, posteroanterior radyografilerde kullanılan anatomik ve dişsel noktaların tekrarlanabilirliğini bilgisayar programı ile belirlemektir.Gereç ve Yöntem: Çalışmada kullanılan röntgenler Kırıkkale Üniversitesi Diş Hekimliği Fakültesi Anabilim dalından alınmıştır. Röntgenler Ankara Üniversitesi Diş Hekimliği Fakültesi Anabilimdalında Dolphin 3D sefalometrik analiz programı ile ölçülmüştür filmlerde belirlenen 22 nokta 3 araştırmacı tarafından tekrarlanabilirliği test edilmiştir.Bulgular: Çalışmanın sonucuna göre iskeletsel noktalar dişsel noktalara göre daha güvenilirdir. En az güvenilir iskeletsel nokta zigomatiko-frontal sutur iken mandibular kanin en güvenilir dental noktadır. Sonuç: Çalışmada ayrıca iki düzlem değerlendirilmiş ve beklenmedik şekilde okluzal düzlem midsagittal düzleme göre daha güvenilir bulunmuştur.

🔖

Cite This Article

ALTUĞ, B., DEMİREL, E., ÖZDİLER, P. D. E. (2020). Repeatability of the Points Used in Posteroanterior Radiography Measurements. European Annals of Dental Sciences, Cilt: 47 - Sayı: 1-3, 75–80. https://ajindex.com/articles/757263

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Ricketts RM, Bench R, Hilgers J, Schulhof R. An overview of computerized cephalometrics. Am J Orthod 1972; 61: 1–28 2. Grummons DC, Kappeyne van de Coppello MA. Frontal asymmetry analysis. J Clin Orthod 1987; 21: 448–465 3. SNODELL SF, NANDA RS, CURRIER GF. A longitudinal cephalometric study of transverse and vertical craniofacial growth. American Journal of Orthodontics and Dentofacial Orthopedics,1993; 104, 471-483 4. ATHANASIOU AE. Orthodontic cephalometry. American Journal of Orthodontics and Dentofacial Orthopedics, 1997; 111, 458-458 5. Grayson BH, McCarthy JG, Bookstein F. Analysis of craniofacial asymmetry by multiplane cephalometry. Am J Orthod 1983; 84: 217-224 6. EL-MANGOURY NH, SHAHEEN SI, MOSTAFA YA. Landmark identification in computerized posteroanterior cephalometrics. American Journal of Orthodontics and Dentofacial Orthopedics, 1987; 91, 57-61. 7. GHAFARI J, CATER PE, SHOFER FS. Effect of film-object distance on posteroanterior cephalometric measurements: suggestions for standardized cephalometric methods. American Journal of Orthodontics and Dentofacial Orthopedics, 1995; 108, 30-37 8. MAJOR PW, JOHNSON DE, HESSE KL, GLOVER KE. Landmark identification error in posterior anterior cephalometrics. The Angle Orthodontist, 1994; 64, 447-454 9. ATHANASIOU A, MIETHKE R, VAN DER MEIJ A. Random errors in localization of landmarks in postero-anterior cephalograms. Journal of Orthodontics, 1999; 26, 273-284 10.LEONARDI R, ANNUNZIATA A, CALTABIANO M. Landmark Identification Error in Posteroanterior Cephalometric Radiography: A Systematic Review. The Angle Orthodontist, 2008; 78, 761-765 11.YOON Y-J, KIM D-H, YU P-S, KIM H-J, CHOI E-H, KIM K-W. Effect of head rotation on posteroanterior cephalometric radiographs. The Angle orthodontist, 2002; 72, 36-42 12.VAN VLIJMEN O, BERGÉ S, BRONKHORST E, SWENNEN G, KATSAROS C, KUIJPERS-JAGTMAN A. A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls. International journal of oral and maxillofacial surgery, 2009; 38, 773-778. 13.RICKETTS R.M. Perspectives on the clinical application of cephalometrics. Angle Orthod 1981; 51: 115-150 14.RUDOLPH D.J., SINCLAIR P.M., COGGINS J.M. Automatic computerized radiographic identification of cephalometric landmarks. Am J Orthod Dentofacial Orthop 1998; 113: 173-179 15.R Leonardia; A Annunziatab; M Caltabianoc. Landmark Identification Error in Posteroanterior Cephalometric Radiography. Angle Orthodontist 200