The article is presented keeping in view of carrying out different studies for titanium dental implant and alloys and aims to evaluate galvanic corrosion around developed titanium dental implants

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Titanium has long been regarded as an inert and biocompatible metal, ideal for biomedical applications such as dental implants or joint replacements.
📊
Key Findings & Data:However, concerns about the biocompatibility of Ti have lately arisen.
💡
Conclusion & Impact:The article is presented keeping in view of carrying out different studies for titanium dental implant and alloys and aims to evaluate galvanic corrosion around developed titanium dental implants
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Dental · İmplant · Titanyum

Abstract

Titanium has long been regarded as an inert and biocompatible metal, ideal for biomedical applications such as dental implants or joint replacements. However, concerns about the biocompatibility of Ti have lately arisen. In spite of recent innovative metallurgical and technological advances and remarkable progress in the design and development of surgical and dental materials, failures do occur. One of the reasons for these failures can be corrosion of dental implants. When the mechanisms that ensure implant bioacceptance and structural stabilization are fully understood, implant failures will become a rare occurrence, provided that they are used properly and placed in sites for which they are indicated. The article is presented keeping in view of carrying out different studies for titanium dental implant and alloys and aims to evaluate galvanic corrosion around developed titanium dental implants

Özet

Titanyum (Ti), biyouyumlu ve inert bir materyaldir. Bu nedenle biomedikal uygulamaların yapıldığı diş hekimliği ve ortopedi gibi alanlarda sıklıkla kullanılmaktadır. Ancak son zamanlarda titanyumun biyouyumluluğu hakkında olumsuz düşünceler ileri sürülmektedir. Ti ve alaşımlarının korozyona uğraması ve oluşan korozyon ürünlerinin kandaki ve dokulardaki seviyesi günümüzde bilim adamlarınca tartışılmaktadır. Günümüzde metalurjik ve teknikolojik gelişmelere, ve cerrahi ve dental materyal tasarımlarındaki ilerlemelere rağmen, dental implantlarda başarısızlıklar görülebil- mektedir. Bu durumun nedenlerinden birisi de koroz- yon olabilir. İmplantların biyolojik olarak vücut tara- fından kabul edilebilmesi ve yapısal bütünlüğünün korunması tam olarak anlaşılabildiğinde, implant kaybı çok nadir görülen bir olay haline gelebilir. Bu makalede titanyum dental implant ve alaşımlarını inceleyen araştırmaların sunulması ve titanyum dental implantlar etrafında oluşan galvanik korozyonun değerlendirilmesi amaçlamaktadır.

🔖

Cite This Article

KAZANCIOĞLU, H., KILIÇ, S., AK, G. (2015). CORROSION IN TITANIUM DENTAL IMPLANTS. Current Research in Dental Sciences, Cilt: 24 - Sayı: Supplement 8, 82–87. https://ajindex.com/articles/736087

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. McGarry S, Morgan SJ, Grosskreuz RM, Williams AE, Smith WR. Serum titanium levels in individuals undergoing intramedullary femoral nailing with titanium implant. J Trauma 2008;64:430-3.
  2. Adya N, Alam M, Ravindranath T, Mubeen A, Saluja B. Corrosion in titanium dental implants: literature review. J Indian Prosth Soc 2005;5:1126- 231. Taş AC. Synthesis of Biomimetic Ca-Hydroxyapatite Powders at 37ºC in Synyhetic BodyFluids. Biomaterials 2000;21:1429-38.
  3. Frisken KW, Dandie GW, Lugowski S, Jordan G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J 2002;47:214-7.
  4. Browne M, Gregson PJ. Surface Modification of Titanium 1993;15:894-8. Biomaterials Van Noort R. Titanium: The Implant Mater of Today. J Material Science 1987;22: 3801-11.
  5. Brune D, Evje DM, Melsom S. Corrosion of gold alloys and titanium in artificial saliva. Scand J Dent Research 1982;90:168-71.
  6. Meyer U, Bühner M, Büchter A, Kruse-Löster B, Stamm T, Wiesmann HP. Fast element mapping of titanium wear around implants of different surface structures. Clin Oral Implants Res 2006;17:206-11.
  7. Bergman M, Bergman B, Söremark R. Tissue accumulation of nickel released due to electrochemical corrosion of non-precious dental casting alloys. J Oral Rehabil 1980;7:325-30.
  8. Wright DC, Gallant RF, Spangberg L. Correlation of corrosion behavior and cytotoxicity in Au-Cu-Ag ternary alloys. J Biomed Material Research 1982;16:509-17.
  9. Clark GCF, Williams DF. The effects of proteins on metallic corrosion. J Biomed Material Research 1982;16:125-34. Chaturvedi TP. An overview of the corrosion aspect of dental implants. Indian J Dent Res. 2009;20:91- 8. Jacobs JJ, Gilbert JL, Urbani RM. Corrosion of metal orhopaedic implants. J Bone Joint Surg Am 1988;80:268-82. Rae T. The biological response to titanium and titanium-aluminum-vanadium Biomaterials 1986;7:30-6. alloy particles. Sedarat C, Harmand MF, Naji A, Nowzari H. In vitro kinetic evaluation of titanium alloy biodegradation. J Periodontal Res 2001;36:269-74. Sarmiento-González A, Marchante-Gayón JM, Tejerina-Lobo JM, Paz-Jiménez J, Sanz-Medel A. ICP-MS multielemental determination of metals potentially released from dental implants and articular prostheses in human biological fluids. Anal Bioanal Chem 2005;382:1001-9.
  10. Berg E, Wagner WC, Davik G, Doota ER. Mechanical properties of laser welded cast and wrought titanium. J Prost Dent 1995;74:250-7.
  11. Chern Lin JH, Ju CP. Biocorrosion st