Journals / Current Research in Dental Sciences / 2021 / Cilt: 31 - Sayı: 1

THE EFFECT OF OPERATOR'S EXPERIENCE ON THE CYCLIC FATIGUE RESISTANCE OF ONE CURVE, 2SHAPE AND RECIPROC NITI FILE SYSTEMS

Pages
46–51
Publication Date
2021-01-15
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Anahtar Kelimeler: Döngüsel yorgunluk, deneyimli operatör, Reciproc, OneCurve, 2Shape,

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: The objective of this study was to compare the resistance to cyclic fatigue of One Curve (OC), 2Shape (TS), and Reciproc (RC) files by considering the operator’s experience.
📊
Key Findings & Data:Materials and methods: Mesial root canals of ninety mandibular molar teeth were prepared by three endodontic residents during the first 6 months of their training (IE) or by three professionals with min. 5 years of endodontic training at postgraduate level (E).
💡
Conclusion & Impact:Anahtar Kelimeler: Döngüsel yorgunluk, deneyimli operatör, Reciproc, OneCurve, 2Shape,
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cyclic fatigue · experienced operator · Reciproc

Abstract

Aim: The objective of this study was to compare the resistance to cyclic fatigue of One Curve (OC), 2Shape (TS), and Reciproc (RC) files by considering the operator’s experience. Materials and methods: Mesial root canals of ninety mandibular molar teeth were prepared by three endodontic residents during the first 6 months of their training (IE) or by three professionals with min. 5 years of endodontic training at postgraduate level (E). Then, 45 files used by the inexperienced group (IE-OC, IE-TS, and IE-RC), 45 files used by the experienced group (E-OC, E-TS, and E-RC), and new 45 files (control group; C-OC, C-TS, and C-RC) were rotated in simulated canals until separation failure occurred. (n=15) The time to fracture was calculated. For statistical analysis, ANOVA and Tukey’s post hoc tests were used (P<0.05). Results: When compared to the experienced and inexperienced groups, the time-to-fracture of control group files was found to be significantly higher (P<0.05). Comparing the experienced and inexperienced operator groups, no significant difference was found for RC files, whereas significant differences were determined for TS and OC files (P<0.05). Conclusions: The residual fatigue life of TS and OC instruments may be decreased by inexperienced operators more than experienced operators. Single file RC instrument was, however, not affected by the operator’s experience. Keywords: Cyclic fatigue, experienced operator, Reciproc, OneCurve, 2Shape, Operatör deneyiminin One Curve, 2Shape ve Reciproc eğe sistemlerinin döngüsel yorgunluk direncine etkisi ÖZ Amaç: Bu çalışmanın amacı, operatör deneyimini dikkate alarak One Curve (OC; Micro-Mega, Besancon, Cedex, Fransa), 2Shape (TS; Micro-Mega) ve Reciproc (RC; VDW, Münih, Almanya) eğelerin döngüsel yorulma direnclerini karşılaştırmaktır. Gereç ve Yöntem: Doksan mandibular molar dişin mezial kök kanalları, eğitimlerinin ilk 6 ayındaki üç endodonti uzmanlık öğrencisi (IE) tarafından veya doktora düzeyinde min. 5 yıllık endodontik eğitim almış üç uzman (E) tarafından prepare edildi. Ardından, deneyimsiz grup tarafından kullanılan 45 eğe (IE-OC, IE-TS ve IE-RC), deneyimli grup tarafından kullanılan 45 eğe (E-OC, E-TS ve E-RC) ve yeni 45 eğe (kontrol grubu; C-OC, C-TS ve C-RC) kırık oluşana kadar simüle edilmiş kanallarda döndürüldü. (n = 15) Eğelerin kırılma süreleri hesaplandı. ANOVA ve Tukey’s post hoc testleri istatistiksel analiz için kullanıldı (P <0.05). Bulgular: Kontrol grubundaki eğe sistemlerinin kırılma zamanı deneyimli ve deneyimsiz grubunkine göre anlamlı derece daha yüksek bulunmuştur (P<.05). Deneyimli ve deneyimsiz operatörlerin grupları karşılaştırıldığında RC eğeleri için anlamlı fark bulunmamışken, TS ve OC eğeleri için anlamlı fark bulunmuştur (P<.05). Sonuç: Bu çalışmada, TS ve OC eğelerin rezidüel yaşam ömrü deneyimli operatörlere kıyasla deneyimsiz operatörlerde daha fazla azaltılmıştır. Tek eğe RC sistemler ise operatörün deneyiminden etkilenmemiştir. Anahtar Kelimeler: Döngüsel yorgunluk, deneyimli operatör, Reciproc, OneCurve, 2Shape,

Özet

Aim: The objective of this study was to compare the resistance to cyclic fatigue of One Curve (OC), 2Shape (TS), and Reciproc (RC) files by considering the operator’s experience. Materials and methods: Mesial root canals of ninety mandibular molar teeth were prepared by three endodontic residents during the first 6 months of their training (IE) or by three professionals with min. 5 years of endodontic training at postgraduate level (E). Then, 45 files used by the inexperienced group (IE-OC, IE-TS, and IE-RC), 45 files used by the experienced group (E-OC, E-TS, and E-RC), and new 45 files (control group; C-OC, C-TS, and C-RC) were rotated in simulated canals until separation failure occurred. (n=15) The time to fracture was calculated. For statistical analysis, ANOVA and Tukey’s post hoc tests were used (P<0.05). Results: When compared to the experienced and inexperienced groups, the time-to-fracture of control group files was found to be significantly higher (P<0.05). Comparing the experienced and inexperienced operator groups, no significant difference was found for RC files, whereas significant differences were determined for TS and OC files (P<0.05). Conclusions: The residual fatigue life of TS and OC instruments may be decreased by inexperienced operators more than experienced operators. Single file RC instrument was, however, not affected by the operator’s experience. Keywords: Cyclic fatigue, experienced operator, Reciproc, OneCurve, 2Shape, Operatör deneyiminin One Curve, 2Shape ve Reciproc eğe sistemlerinin döngüsel yorgunluk direncine etkisi ÖZ Amaç: Bu çalışmanın amacı, operatör deneyimini dikkate alarak One Curve (OC; Micro-Mega, Besancon, Cedex, Fransa), 2Shape (TS; Micro-Mega) ve Reciproc (RC; VDW, Münih, Almanya) eğelerin döngüsel yorulma direnclerini karşılaştırmaktır. Gereç ve Yöntem: Doksan mandibular molar dişin mezial kök kanalları, eğitimlerinin ilk 6 ayındaki üç endodonti uzmanlık öğrencisi (IE) tarafından veya doktora düzeyinde min. 5 yıllık endodontik eğitim almış üç uzman (E) tarafından prepare edildi. Ardından, deneyimsiz grup tarafından kullanılan 45 eğe (IE-OC, IE-TS ve IE-RC), deneyimli grup tarafından kullanılan 45 eğe (E-OC, E-TS ve E-RC) ve yeni 45 eğe (kontrol grubu; C-OC, C-TS ve C-RC) kırık oluşana kadar simüle edilmiş kanallarda döndürüldü. (n = 15) Eğelerin kırılma süreleri hesaplandı. ANOVA ve Tukey’s post hoc testleri istatistiksel analiz için kullanıldı (P <0.05). Bulgular: Kontrol grubundaki eğe sistemlerinin kırılma zamanı deneyimli ve deneyimsiz grubunkine göre anlamlı derece daha yüksek bulunmuştur (P<.05). Deneyimli ve deneyimsiz operatörlerin grupları karşılaştırıldığında RC eğeleri için anlamlı fark bulunmamışken, TS ve OC eğeleri için anlamlı fark bulunmuştur (P<.05). Sonuç: Bu çalışmada, TS ve OC eğelerin rezidüel yaşam ömrü deneyimli operatörlere kıyasla deneyimsiz operatörlerde daha fazla azaltılmıştır. Tek eğe RC sistemler ise operatörün deneyiminden etkilenmemiştir. Anahtar Kelimeler: Döngüsel yorgunluk, deneyimli operatör, Reciproc, OneCurve, 2Shape,

🔖

Cite This Article

ADIGÜZEL, M. H., YILMAZ, K. (2021). THE EFFECT OF OPERATOR'S EXPERIENCE ON THE CYCLIC FATIGUE RESISTANCE OF ONE CURVE, 2SHAPE AND RECIPROC NITI FILE SYSTEMS. Current Research in Dental Sciences, Cilt: 31 - Sayı: 1, 46–51. https://ajindex.com/articles/735644

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Adiguzel M, Tüfenkçi P. Comparison of the cyclic fatigue resistance of Waveone, Reciproc and Twisted File Adaptive files in canals with a double curvature (s-shaped). J Dent Fac Atatürk Uni 2018; 28:199-203
  2. Adiguzel M, Turgay B. Comparison of the cyclic fatigue resistance of Reciproc and Reciproc Blue nickel-titanium instruments in artificial canals with single and double (s-shaped) curvatures. Eur Endod J 2017; 2:32-32
  3. McGuigan MB, Louca C, Duncan HF. Endodontic instrument fracture: causes and prevention. Br Dent J 2013; 214:341-8
  4. Saleh AM, Tavanafar S, Vakili-Gilani P, Al Sammerraie NJ, Rashid F. Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth. RDE 2013; 38:222-6
  5. Mandel E, Adib-Yazdi M, Benhamou LM, Lachkar T, Mesgouez C, Sobel M. Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J 1999; 32:436-43
  6. Plotino G, Al-Sudani D, Pulino S, Grande NM, Marcoli PA, Pizzi S, Testarelli L, Gambarini G. Cyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators--an in vivo and in vitro study. Med Sci Monit 2012; 18:41-5
  7. Yang Y, Shen Y, Ma J, Cao Y, Haapasalo M. A Micro-computed tomographic assessment of the influence of operator's experience on the quality of WaveOne instrumentation. J Endod 2016; 42:1258-62
  8. Elnaghy AM, Elsaka SE. Cyclic fatigue resistance of One Curve, 2Shape, ProFile Vortex, Vortex Blue, and RaCe nickel-titanium rotary instruments in single and double curvature canals. J Endod 2018; 44:1725-30
  9. Ozyurek T, Gundogar M, Uslu G, Yılmaz K, Staffoli S, Nm G, Plotino G, Polimeni A. Cyclic fatigue resistances of Hyflex EDM, WaveOne Gold, Reciproc Blue and 2shape NiTi rotary files in different artificial canals. Odontology 2018; 106:408–13
  10. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1971: 32:271-5
  11. Yang GB, Zhou XD, Zhang H, Wu HK. Shaping ability of progressive versus constant taper instruments in simulated root canals. Int Endod J 2006; 39:791-9
  12. Ozyurek T, Yilmaz K, Uslu G, Plotino G. The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study. RDE 2018; 43:e10
  13. Munoz E, Forner L, Llena C. Influence of operator's experience on root canal shaping ability with a rotary nickel-titanium