Journals / Academic Platform Journal of Engineering and Smart Systems / 2020 / Cilt: 8 - Sayı: 3

Theoretical and Experimental Investigation of Carbon Monoxide, Humidity and Temperature Relations in Zonguldak Province of Turkey

Türkiye Zonguldak İlinde Karbon Monoksit-Nem-Sıcaklık İlişkisinin Sensörle İzlenmesi ve Hesaplamalı Olarak Modellenmesi

Pages
464–470
Publication Date
2020-09-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was concluded that the system presented in this study might be integrated into CO sensor units to improve the sensor response in terms of accuracy and precision.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The sensor monitoring of ambient carbon monoxide (CO) which was mainly emitted by the coal mines and power plants was performed in the center of Zonguldak province of Turkey.
📊
Key Findings & Data:It was observed that the recorded amount of CO (ppm) highly depended on the amount of humidity (H2O) percent and temperature.
💡
Conclusion & Impact:It was concluded that the system presented in this study might be integrated into CO sensor units to improve the sensor response in terms of accuracy and precision.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:karbon monoksit · nem · sensörlü izleme

Abstract

The sensor monitoring of ambient carbon monoxide (CO) which was mainly emitted by the coal mines and power plants was performed in the center of Zonguldak province of Turkey. It was observed that the recorded amount of CO (ppm) highly depended on the amount of humidity (H2O) percent and temperature. The sensor monitored higher CO values at higher temperatures accompanied with lower humidity percent whereas lower CO values at lower temperatures accompanied with higher humidity percent. Consequently, OC…Wn (W: H2O) (n = 1-3) long-range (hydrogen-bonding) interactions were modelled computationally using MP2/6-311++G(d,p) level of theory at selected temperatures. The calculated interaction Gibbs free energies and performed reactivity and stability analyses supported the possibility of carbon monoxide and humidity interactions at lower temperatures with higher humidity percent in parallel with the experimental results. It was concluded that the system presented in this study might be integrated into CO sensor units to improve the sensor response in terms of accuracy and precision.

Özet

Esas olarak kömür madenleri ve enerji santralleri tarafından yayılan karbon monoksitinin (CO) sensörlü izlemesi Türkiye'nin Zonguldak il merkezinde gerçekleştirilmiştir. Kaydedilen CO (ppm) miktarının büyük ölçüde nem (H2O) yüzdesine ve sıcaklığa bağlı olduğu gözlemlenmiştir. Yüksek sıcaklıklarda ve düşük nem yüzdelerinde yüksek CO miktarları ölçülürken, düşük sıcaklıklarda ve daha yüksek nem yüzdelerinde daha düşük CO seviyeleri ölçülmüştür. Buna bağlı olarak, OC… Wn (W: H2O) (n = 1-3) şeklindeki uzak etkileşimler, seçilen sıcaklıklarda ve MP2/6-311++G(d,p) teori seviyesi kullanılarak hesaplamalı olarak modellenmiştir. Hesaplanan etkileşim Gibbs serbest enerjileri ve gerçekleştirilen reaktivite ve stabilite analizleri, deney sonuçlarına paralel olarak, düşük sıcaklıklarda ve yüksek nem oranlarında karbon monoksit-nem etkileşimleri olasılığını desteklemiştir. Bu çalışmada sunulan sistemin, sensör değerlerini doğruluk ve kesinlik açısından iyileştirmek için, CO sensör ünitelerine entegre edilebileceği sonucuna varılmıştır.

🔖

Cite This Article

BAYAR, C. C. (2020). Theoretical and Experimental Investigation of Carbon Monoxide, Humidity and Temperature Relations in Zonguldak Province of Turkey. Academic Platform Journal of Engineering and Smart Systems, Cilt: 8 - Sayı: 3, 464–470. https://ajindex.com/articles/730620

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. P. Wei, Z. Ning, S. Ye, L. Sun, F. Yang, K.C. Wong, D. Westerdahl and P.K.K. Louie, “Impact analysis of temperature and humidity conditions on electrochemical sensor response in ambient air quality monitoring,” Sensors, vol. 18, no 2, pp. 59, Feb. 2018
  2. W. Yi, K. Lo, T. Mak, K. Leung, Y. Leung and M.A. Meng, “Survey of wireless sensor network based air pollution monitoring systems,” Sensors, vol. 15, no 12, pp. 31392-31427, Dec. 2015
  3. W. Jiao, G. Hagler, R. Williams, R. Sharpe, R. Brown, D. Garver, R. Judge, M. Caudill, J. Rickard, M. Davis, L. Weinstock, S. Zimmer-Dauphinee and K. Buckley, “Community air sensor network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United States,” Atmos. Meas. Tech., vol. 9, no 11, pp. 5281-5292, Nov. 2016
  4. L. Spinelle, M. Gerboles, M.G. Villani, M. Aleixandre and F. Bonavitacola, “Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2,” Sens. Actuators, B, vol. 238, pp. 706-715, Jan. 2017
  5. M. Aleixandre and M. Gerboles, “Review of small commercial sensors for indicative monitoring of ambient gas,” Chem. Eng. Trans., vol. 30, pp. 169-174, Sep. 2012
  6. G. Whitenett, G. Stewart, K. Atherton, B. Culshaw and W. Johnstone, “Optical fibre instrumentation for environmental monitoring applications,” J. Opt. A: Pure Appl. Opt., vol. 5, no 5, pp. S140-S145, Sep. 2003
  7. G.F. Fine, L.M. Cavanagh, A. Afonja and R. Binions, “Metal oxide semi-conductor gas sensors in environmental monitoring,” Sensors, vol. 10, no 6, pp. 5469-5502, Jun. 2010
  8. M.I. Mead, O.A.M. Popoola, G.B. Stewart, P. Landshoff, M. Calleja, M. Hayes, J.J. Baldovi, M.W. McLeod, T.F. Hodgson, J. Dicks, A. Lewis, J. Cohen, R. Baron, J.R. Saffell and R.L. Jones, “The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks,” Atmos. Environ., vol. 70, pp. 186-203, May 2013
  9. C. Lin, J. Gillespie, M.D. Schuder, W. Duberstein, I.J. Beverland and M.R. Heal, “Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide,” Atmos. Environ., vol. 100, pp. 111-116, Jan. 2015
  10. L. Spinelle, M. Gerboles, M.G. Villani, M. Aleixandre and F. Bonavitacola, “Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxide,” Sens. Actuators, B, vol. 215,