Journals / Acta Materialia Turcica / 2020 / Cilt: 4 - Sayı: 4

The Philosophy of Laser Imaging

Pages
1–7
Publication Date
2020-10-23
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this review paper, the philosophical concept will be evaluated for laser imaging.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The philosophy of laser imaging first thought by the idea of visualizing the photon trajectories which are even seen by naked eyes when anybody looks inside to the photon diffusing object.
📊
Key Findings & Data:Most of the diffuse optic laser imaging technique are using low energy incident collimated isotropic un-polarized gaussian beam which is generated by semiconductor laser diode.
💡
Conclusion & Impact:In this review paper, the philosophical concept will be evaluated for laser imaging.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Biomedical Imaging · Diffuse optic tomography (DOT) technique · transmission through

Abstract

The philosophy of laser imaging first thought by the idea of visualizing the photon trajectories which are even seen by naked eyes when anybody looks inside to the photon diffusing object. If white light beams onto the imaging tissue, blood vessels can be seen by the naked eye from the tissue surface, roughly. One of the important biomedical molecular macroscopic imaging technique is the laser imaging. Most of the works cover research infrastructures, laboratories, and hospitals for diffuse optic laser imaging. Naturally, in most of the clinical applications, near infrared (NIR) laser is being used, since the main motivation trial is the cancer case, obviously. NIR laser helps to figure out hemoglobin content which uses the blood absorption maxima wavelength, hence in most of diffuse optic tomography (DOT) research, NIR laser is used. Most of the diffuse optic laser imaging technique are using low energy incident collimated isotropic un-polarized gaussian beam which is generated by semiconductor laser diode. Applied power is usually less than 10 mW/cm2. At the beginning of the laser diffuse optic imaging (DOI) research era, most of the researchers have jumped into the research without reading and understanding the limitations of the modality. Low energy light has some restrictions, the most important is the scattering nature of the light depend on the tissue type. However, some tissue types such as cerebrospinal fluid has low optic scattering coefficients. Another important factor besides the scattering, caused by low energy, hence photons are penetrating only superficially. Photons are scattering much and penetrating only superficially. On the other hand, if x-ray bremsstrahlung photons were used, it would go deeper tissue layers, nevertheless it becomes ionized radiative light. The philosophy of laser diffuse macroscopic molecular imaging modality is covering scattering of light, therefore device concept should be thought according to this phenomenon, source and detector placement should be arranged based on this truth. In this review paper, the philosophical concept will be evaluated for laser imaging.

🔖

Cite This Article

KAZANCİ, H. O. (2020). The Philosophy of Laser Imaging. Acta Materialia Turcica, Cilt: 4 - Sayı: 4, 1–7. https://ajindex.com/articles/727629

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Cutler M. “Transillumination as an aid in the diagnosis of breast lesions”. Surg. Gynecol. Obstet. 48:721-8, 1929
  2. S.R. Arridge, Optical tomography in medical imaging, Inverse Probl., 15, 41–93, 1999. DOI:10.1088/0266-5611/15/2/022
  3. S.R. Arridge, J.C. Hebden, Optical imaging in medicine: II. Modelling and reconstruction, Phys. Med. Biol. 1997. 42, 841–853
  4. D.A. Boas, D.H. Brooks, E.L. Miller, C.A. DiMarzio, M. Kilmer, R.J. Gaudette, Q. Zhang, Imaging the body with diffuse optical tomography, IEEE Signal Process. Mag. 18, 2001. 57–75. DOI:10.1109/79.962278
  5. J.P. Culver, R. Choe, M.J. Holboke, L. Zubkov, T. Durduran, A. Slemp, V. Ntziachristos, B. Chance, A.G. Yodh, Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging, Med. Phys., 2003. 30, 235–247. DOI:10.1118/1.1534109
  6. B.W. Pogue, S.C. Davis, X. Song, B.A. Brooksby, H. Dehghani, K.D. Paulsen, Image analysis methods for diffuse optical tomography. J. Biomed. Opt., 2006. 11, 033 001–033 016. DOI:10.1117/1.2209908
  7. Culver J.P. “Statistical analysis of high density diffuse optical tomography”. NeuroImage, 85:01, 2013
  8. B.J. Tromberg, B.W. Pogue, K.D. Paulsen, A.G. Yodh, D.A. Boas, A.E. Cerussi, Assessing the future of diffuse optical imaging technologies for breast cancer management. Med. Phys., 2008. 35, 2443–2451. DOI:10.1118/1.2919078
  9. Xiaofeng Zhang, Instrumentation in Diffuse Optical Imaging. Photonics. 2014; 1(1): 9–32
  10. Boas DA, Dale AM, Franceschini MA. Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy. Neuroimage. 2004;23(Suppl 1):S275–288
  11. Intes X, Chance B. Non-PET functional imaging techniques: optical. Radiologic Clinics of North America. 2005;43:221–234
  12. Hielscher AH. Optical tomographic imaging of small animals. Curr Opin Biotechnol. 2005;16:79–88
  13. Gibson AP, Hebden JC, Arridge SR. Recent advances in diffuse optical imaging. Phys Med Biol. 2005;50:R1–43
  14. Zhao H, Gao F, Tanikawa Y, Yamada Y. Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging. J Biomed Opt. 2007;12:062107
  15. Dehghani H, Srinivasan S, Pogue BW, Gibson A. Numerical modelling and image reconstruction in diffuse optical tomography. Philos Transact A Math Phys Eng Sci. 2009;367:3073–3093
  16. Leblond F, Davis SC, Valdes PA, Pogue BW. Pre-clini