Journals / Turkish Journal of Medical Sciences / 2008 / Cilt: 38 - Sayı: 2

Scalpel Versus Electrocautery Dissections: The Effect on Wound Complications and Pro-Inflammatory Cytokine Levels in Wound Fluid

Pages
111–116
Publication Date
2008-02-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Electrocautery dissection increases pro-inflammatory cytokine response in wound fluid, which may reflect an aggravated inflammation and increased potential for tissue damage.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: Electrocautery has been postulated as a risk factor for wound complications.
📊
Key Findings & Data:Materials and Methods: Patients undergoing modified radical mastectomy were assigned to flap dissection with either electrocautery (n = 18) or scalpel (n = 20).
💡
Conclusion & Impact:Electrocautery dissection increases pro-inflammatory cytokine response in wound fluid, which may reflect an aggravated inflammation and increased potential for tissue damage.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Electrocautery · sharp dissection · seroma

Abstract

Aim: Electrocautery has been postulated as a risk factor for wound complications. This study was conducted to evaluate the effects of electrocautery and scalpel dissections on wound complications and local cytokine levels. Materials and Methods: Patients undergoing modified radical mastectomy were assigned to flap dissection with either electrocautery (n = 18) or scalpel (n = 20). Blood loss, drain volume and duration, seroma formation and wound complications were recorded. Tumor necrosis factor-alpha (TNF-a) and interleukin (IL)-6 levels were measured in drain fluids at postoperative 24 hours. Results: The electrocautery group had significantly reduced blood loss and total drain volume, but increased seroma formation rate. Significantly elevated levels of TNF-aa were measured in drain fluids of patients with electrocautery dissection. Conclusions: The use of electrocautery causes less bleeding and total drain output with an increased rate of seroma formation. Electrocautery dissection increases pro-inflammatory cytokine response in wound fluid, which may reflect an aggravated inflammation and increased potential for tissue damage.

Özet

Aim: Electrocautery has been postulated as a risk factor for wound complications. This study was conducted to evaluate the effects of electrocautery and scalpel dissections on wound complications and local cytokine levels. Materials and Methods: Patients undergoing modified radical mastectomy were assigned to flap dissection with either electrocautery (n = 18) or scalpel (n = 20). Blood loss, drain volume and duration, seroma formation and wound complications were recorded. Tumor necrosis factor-alpha (TNF-a) and interleukin (IL)-6 levels were measured in drain fluids at postoperative 24 hours. Results: The electrocautery group had significantly reduced blood loss and total drain volume, but increased seroma formation rate. Significantly elevated levels of TNF-aa were measured in drain fluids of patients with electrocautery dissection. Conclusions: The use of electrocautery causes less bleeding and total drain output with an increased rate of seroma formation. Electrocautery dissection increases pro-inflammatory cytokine response in wound fluid, which may reflect an aggravated inflammation and increased potential for tissue damage.

🔖

Cite This Article

ÖZDOĞAN, M. (2008). Scalpel Versus Electrocautery Dissections: The Effect on Wound Complications and Pro-Inflammatory Cytokine Levels in Wound Fluid. Turkish Journal of Medical Sciences, Cilt: 38 - Sayı: 2, 111–116. https://ajindex.com/articles/723642

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...