Journals / Politeknik Dergisi / 2026 / Cilt: 6 Sayı: 3

THE HEAT EXCHANGER CAPACITY EFFECTS OF THE PERFORMANCE IN THE NATURAL CIRCULATION INDIRECT HOT WATER PREPARING SYSTEMS BY SOLAR ENERGY

TABİİ SİRKÜLASYONLU GÜNEŞ ENERJİLİ ENDİREKT SICAK SU HAZIRLAMA SİSTEMLERİNDE EŞANJÖR KAPASİTESİNİN VERİME OLAN ETKİSİ

Pages
551–557
Publication Date
2003-09-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, the performance of the system which has 5 lt heat exchanger capacity has been obtained as the best.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this paper, the effect of the performance of the capacities of heat exchanger in the natural circulation indirect hot water preparing systems has been examined.
📊
Key Findings & Data:The systems that all properties are the same and the heat exchanger capacities are different performance experiments have been done.
💡
Conclusion & Impact:As a result, the performance of the system which has 5 lt heat exchanger capacity has been obtained as the best.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Güneş enerjisi · eşanjör kapasitesi · verim.

Abstract

In this paper, the effect of the performance of the capacities of heat exchanger in the natural circulation indirect hot water preparing systems has been examined. The systems that all properties are the same and the heat exchanger capacities are different performance experiments have been done. The result of experiments, the performans of the system which the heat exchanger capacity is 15 lt – 41 %, 10 lt – 44 %, 5 lt 47 % and 2 lt 38 %. As a result, the performance of the system which has 5 lt heat exchanger capacity has been obtained as the best.

Özet

Bu makalede, Tabii sirkülasyonlu endirekt sıcak su hazırlama sistemlerinde eşanjör kapasitelerinin verime olan etkisi incelenmiştir. Bütün özellikleri aynı eşanjör kapasiteleri farklı olan sistemlerin performans deneyleri yapılmıştır. Deneyler sonunda, 15 lt’ lik eşanjör kapasiteli sistemin verimi % 41, 10 lt ’lik eşanjör kapasiteli sistemin verimi % 44, 5 lt ’lik eşanjör kapasiteli sistemin verimi % 47 ve 2 lt ’lik eşanjör kapasiteli sistemin verimi % 38 olarak tespit edilmiştir. Elde edilen bu sonuçlara göre 5 litre ’lik eşanjör kapasitesine sahip olan sistemin veriminin en iyi olduğu tespit edilmiştir.

🔖

Cite This Article

Özkaya, M. G., Variyenli, H. İ. (2003). THE HEAT EXCHANGER CAPACITY EFFECTS OF THE PERFORMANCE IN THE NATURAL CIRCULATION INDIRECT HOT WATER PREPARING SYSTEMS BY SOLAR ENERGY. Politeknik Dergisi, Cilt: 6 Sayı: 3, 551–557. https://ajindex.com/articles/697185

📄 Full Text PDF Viewer

📄