Journals / Karaelmas Fen ve Mühendislik Dergisi / 2016 / Cilt: 6 - Sayı: 2

Determination of Trace Amounts of Zirconium and Fluoride in Tap Water and BottledWater Samples Using High Performance Liquid Chromatography

Yüksek Performanslı Sıvı Kromatografi ile Musluk Suyu ve Şişelenmiş Su Örneklerinde Zirkonyum ve Florürün Eser Miktarlarının Belirlenmesi

Pages
321–328
Publication Date
2016-06-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The sensitivity; precision and accuracy of the method are all satisfactory.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The determination of trace amountsof zirconium and fluoride in various matrixes tap and bottled water were investigated by high performance reversed phase liquid chromatography.
📊
Key Findings & Data:High performance liquid chromatography HPLC was used for determinationof zirconium and fluoride based on their formed complex with 2- 5-bromo-2-pyridylazo -5-diethylaminophenol 5-Br-PADAP .
💡
Conclusion & Impact:The sensitivity; precision and accuracy of the method are all satisfactory.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Fluorür · HPLC · PADAP

Abstract

The determination of trace amountsof zirconium and fluoride in various matrixes tap and bottled water were investigated by high performance reversed phase liquid chromatography. High performance liquid chromatography HPLC was used for determinationof zirconium and fluoride based on their formed complex with 2- 5-bromo-2-pyridylazo -5-diethylaminophenol 5-Br-PADAP . Solid-phase extraction SPE along with high performance liquid chromatographywas used for the analysis. Under optimum conditions, the detection limits for Zr IV and flouride were 0.4 ug/L, and 0.015 ug/L, respectively. Recoveries, 99.74–104.33% for Zr IV and 93.33-106.67% for fluoride were obtained. The sensitivity; precision and accuracy of the method are all satisfactory.

Özet

Eser miktarlardaki zirkonyum ve florürün belirlenmesi için, çeşitli matrisler musluk ve şişelenmiş su yüksek performanslı tersfaz sıvı kromatografi ile incelendi. Yüksek performanslı sıvı kromatografisi, zirkonyum ve fluorürün, 2- 5-brom-2-piridilazo -5diethylaminophenol 5-Br-PADAP ile oluşturduğu kompleks üzerinden belirlenmesi için kullanıldı. Katı faz ekstraksiyonu SPE , yüksek performanslı sıvı kromatografisi ile birlikte analiz için kullanıldı. Optimum koşullar altında, Zr IV ve florür için dedeksiyon limitleri sırasıyla 0.4 µg/L ve 0.015 µg/L olarak bulundu. Geri kazanım, Zr IV için % 99.74-104.33 ve florür için % 93.33-106.67 elde edildi. İçme suları, Isparta ve Burdur’un farklı noktalarından toplandı. Şişe suları farklı marketlerden temin edildi. Metodun, duyarlılık, yöntem kesinliği ve doğruluğu parametreleri diğer metodlarla karşılaştırıldığında yeterlidir

🔖

Cite This Article

CANBAY, H. S., ALSANCAK, G. (2016). Determination of Trace Amounts of Zirconium and Fluoride in Tap Water and BottledWater Samples Using High Performance Liquid Chromatography. Karaelmas Fen ve Mühendislik Dergisi, Cilt: 6 - Sayı: 2, 321–328. https://ajindex.com/articles/684033

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Abbaspour, A., Baramakeh, L. 2002. Simultaneous determination of zirconium and molybdenum by first-derivative spectrophotometry. Anal Sci., 18:1127–1130.
  2. Afzali, D., Fathirad, F., Ghaseminezhad, S., Afzali, Z. 2014. Determination of trace amounts of zirconium in real samples after microwave digestion and ternary complex dispersive liquid–liquid microextraction. Environ Monit Assess., 186:3523–3529.
  3. Alimarin, IP., Fadeeva, VI., Kudryavtsev, GV., Lokutova, IM., Tikhomirova, TI. 1987. Concentration, separation and determination of scandium, zirconium, hafnium and thorium with a silica-based sulphonic acid cation-exchanger. Talanta., 34:103–110.
  4. Amin, AS. 2015. Novel approach for the determination of zirconium by solid-phase spectrophotometry. JTUSCI., 9: 227–236. ASTM:D1179 B. 2010. Standard Test Methods for Fluoride Ion in Water. ASTM International, West Conshohocken, PA. ASTM D4327 – 97. 1991. Standard Test Method for Anions in Water by Chemically Suppressed Ion Chromatography. ASTM International, West Conshohocken, PA. Savik, E., Demer, S., Memis, U., Kumbul Doguc, D., Calıskan, T.A., Tugrul Sezer, M., Gültekin, F., Özgür, N. 2012. Isparta ve civarında tüketilen suların içerik ve sağlık açısından değerlendirilmesi. SDÜ Tip Fak Derg., 19(3):92-102.
  5. Secilmiş, H., Karipcin, F., Alsancak, G. 2004. The Investigation of RP-LC of Zr(IV)(5-Br-PADAP) and Hf(IV) (5-Br- PADAP) complexes in methanol water binary mixtures. 4th Aegean Analytical Chemistry Days, pp. 95, Aydın, Turkey. Shariati, S. Yamini, Y., Zanjani M.K. 2008. Simultaneous preconcentra-tion and determination of U(VI), Th(IV), Zr[IV] and Hf(IV) ions in aqueou ssamples using micelle- mediated extraction coupled to inductively coupled plasma- optical emission spectrometry. J Hazard Mater., 156: 583–590.
  6. Shariati, S., Yamini, Y. 2006. Cloud point extraction and simultaneous determination of zirconium and hafnium using ICP-OES. J Colloid Interface Sci., 298:419–425.
  7. Shervedani, R.K., Bagherzadeh, M. 2009. Electro chemical impedance spectroscopy as a trans duction method for electro chemical recognition of zirconium on gold electrode modified with hydroxamated self-assembled monolayer. Sens Actuators B., 139:657–664.
  8. Sreedevi, P.D., Ahmed, S., Made, B., Ledoux, E., Gandolfi, J.M. 2006. Association of hydrogeological factors in the temporal variations of fluoride concentration in a crystalline aquifer India. Environ Geol., 50(1):1–11. Standard Method 4110. 1992. Standard Methods for the Examination of Water