Journals / International Journal of Environment and Geoinformatics / 2015 / Cilt: 2 - Sayı: 2

Assessment Of Stability and Energy Dissipation Performances of an Antifer Layer Protected Caisson

Pages
88–104
Publication Date
2015-08-03
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Although OC was tested under shorter durations and had a more favorable superstructure in terms of resisting forces, the results indicated that APC was significantly more stable.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The present study intends to assess the stability and energy dissipation performances of a breakwater configuration (APC) protected by an antifer layer.
📊
Key Findings & Data:For comparison, an ordinary caisson (OC), which was 5% wider and 10% heavier, was also investigated.
💡
Conclusion & Impact:Although OC was tested under shorter durations and had a more favorable superstructure in terms of resisting forces, the results indicated that APC was significantly more stable.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Antifer protected caisson · Caisson displacements · Stability performance

Abstract

The present study intends to assess the stability and energy dissipation performances of a breakwater configuration (APC) protected by an antifer layer. For comparison, an ordinary caisson (OC), which was 5% wider and 10% heavier, was also investigated. Physical models were implemented and tested under regular and irregular waves; and resulting linear and angular displacements were directly measured via a photogrammetric method. Additionally, wave forces and resulting horizontal displacements were estimated both from recorded pressure data and from individual incident waves by modified Goda method. To calculate the horizontal displacement, the estimated wave force time series were directly double-integrated, whilst the theoretical method proposed by Shimosako et al. (1994) were used on the individual force values. Although OC was tested under shorter durations and had a more favorable superstructure in terms of resisting forces, the results indicated that APC was significantly more stable. Energy dissipation performance of the tested configurations were quantified in terms of spectral averaged and phase resolved reflection coefficients, whereas antifer damage ratio was measured on a block-count basis. Results indicated that the APC configuration had an enhanced performance of dissipating the wave energy; moreover, the dissipated energy directly links to antifer damage ratio.

🔖

Cite This Article

ŞEKER, D. Z., KABDAŞLI, M. S., ÇELİKOYAN, M., GAZİOĞLU, C. (2015). Assessment Of Stability and Energy Dissipation Performances of an Antifer Layer Protected Caisson. International Journal of Environment and Geoinformatics, Cilt: 2 - Sayı: 2, 88–104. https://ajindex.com/articles/672673

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. CEM Coastal Engineering Manual (2006)
  2. U.S. Army Corps of Engineers, Washington, D.C. Goda, Y. (1967) “The fourth order approximation to the pressure of standing waves,” Coastal Engineering in Japan, 10, 1–11.
  3. Goda, Y. (1985) “Random seas and design of maritime structures”, University of Tokyo Press,
  4. Japonya. Goda Y. (1994) “Dynamic response of upright breakwater to impulsive force of breaking wave,” Coastal Engineering, 22(1,2), 135 –158. Goda Y. (2008) “Lecture notes of seminar on recent developments in coastal engineering by Prof. Y. Goda”, 21-22 May 2008, METU Cultural & Convention Centre, Ankara.
  5. Goda Y. (2010) “Reanalysis of regular and random breaking wave statistics,” Coastal Engineering Journal, 52(1), 71-106.
  6. Kim, T-M & Takayama T. (2003) “Computational improvement for expected sliding distance of a caisson-type breakwater by introduction of a doubly-truncated normal distribution,” Coastal Engineering Journal, 45(3), 387– 419. Kirca, V.S.O (2008) “Effect of frontface configuration on the performance of vertical faced coastal structures,” PhD Thesis, Coastal Sciences and Engineering Programme, Institute of Sci. & Tech., Istanbul Technical University, Istanbul. Kirca, V.S.O. & Kabdasli, M.S. (2009) “Reduction of non-breaking wave loads on caisson type breakwaters using a modified perforated configuration,” Ocean Engineering, 36, 1316-1331.
  7. Kirca, V. S., Kabdasli, M. S., Seker, D. Z., & Celikoyan, M. (2013) “Stability and Energy Dissipation of an Antifer Layer Protected Caisson.” In The Twenty-third International Offshore and Polar Engineering Conference, ISOPE 2013, June 30-July 5, Anchorage, AL, USA. Ling, H.I., Cheng, A. H.-D., Mohri,Y & Kawabata, T. (1999) “Permanent displacement of composite breakwaters subject to wave impact,” J. Wtrwy. Port, Coast., and Oc. Engrg., ASCE, 125(1), 1–8.
  8. Liu, P.L.-F., Lin, P., Chang, K.-A. & Sakakiyama T. (1999) “Numerical modeling of wave interaction with porous structures,” J. Wtrwy. Port, Coast., and Oc. Engrg., ASCE, 125(6), 322–330. NAVFAC (Naval Facilities Engineering Command) (1986) “Design Manual DM7-02: Foundations and Earth Structures”, p. 7.2-63,
  9. Virginia. Oumeraci, H. (1994) “Review and analysis of vertical breakwater failures—lessons learned,” Coastal Engineering, 22, 3–29. Oumeraci H. & Kortenhaus A. (1994) “Analysis of the dynamic response of caisson breakwater,” Coastal Engineering, 22(1; 2): 159 –183. Sakakiyama T. & Liu, P.L.-F. (2001) “Laboratory experiments for wave motions and turbulence flows