Journals / Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2022 / Cilt: 15 - Sayı: 2

Breast Tumor Detection and Classification Based on Microwave Imaging

Pages
622–635
Publication Date
2022-08-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Performance of the proposed approach was tested for two different antenna array resolutions, and it was observed that this parameter is important for successful detection and classification of a tumor-site in a realistic heterogenous breast tissue model.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Limitations caused by traditional breast cancer detection and screening techniques have encouraged researchers to investigate alternative solutions.
📊
Key Findings & Data:All calculations, in the study, were performed computationally in terms of a 3D Finite-Difference Time-Domain (FDTD) simulation models.
💡
Conclusion & Impact:Performance of the proposed approach was tested for two different antenna array resolutions, and it was observed that this parameter is important for successful detection and classification of a tumor-site in a realistic heterogenous breast tissue model.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:confocal microwave imaging · 3D FDTD · matched-filtering

Abstract

Limitations caused by traditional breast cancer detection and screening techniques have encouraged researchers to investigate alternative solutions. This study examines the use of a microwave-based approach for tumor detection in breast tissue and related tumor type classification using matched-filtering. Radar-like confocal microwave imaging (CMI) method constructs the foundation of such tumor detection approach. In particular, a microwave pulse is first transmitted, then back-scattered pulses are collected. All major reflective sites in the breast tissue are detected by repeating this procedure on a microwave pulse transmission-reception grid, aligning captured signals in-time to focus on a particular region in the breast tissue and superimposing such time-shifted signals to improve signal-to-clutter level. In the observed signals, clutter is originated by the heterogeneity of the breast tissue while signal is originated by a tumor site as a function of its water content. All calculations, in the study, were performed computationally in terms of a 3D Finite-Difference Time-Domain (FDTD) simulation models. For the antenna system, two cross-polarized resistively loaded bow-ties antennas were used in the computational model, and the tumor site was modeled using five different size and morphologies. Matched-filtering, on the other hand, was performed matching such obtained observations with that of a homogenous breast tissue, namely clutter-free model. Performance of the proposed approach was tested for two different antenna array resolutions, and it was observed that this parameter is important for successful detection and classification of a tumor-site in a realistic heterogenous breast tissue model.

🔖

Cite This Article

ORAL, E. A., SAHAKİAN, A. V. (2022). Breast Tumor Detection and Classification Based on Microwave Imaging. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 15 - Sayı: 2, 622–635. https://ajindex.com/articles/664263

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. American Cancer Society. Cancer Facts & Figures 2021; American Cancer Society: Atlanta, GA, USA, 2021. Available online: https://www.cancer.org/research/cancer-facts-statistics/all-cancer-facts-figures/cancer-facts-figures-2021.html (accessed on 21 April 2022)
  2. S. Kwon, S. Lee, “Recent advances in microwave imaging for breast cancer detection”, Int. J. Biomed. Imaging. 2016, 5054912 S.G. Orel, M.D. Schnall, “MR imaging of the breast for the detection, diagnosis, and staging of breast cancer”, Radiology 2001, 220, 13–30
  3. M.A. Aldhaeebi, T.S. Almoneef, H. Attia, O.M. Ramahi, “Near-Field Microwave Loop Array Sensor for Breast Tumor Detection”, IEEE Sens. J. 2019, 19, 11867-11872
  4. B. Bocquet, J. Van de Velde, A. Mamouni, Y. Leroy, G. Giaux, J. Delannoy, D. Delvalee, “Microwave radiometric imaging at 3 GHz for the exploration of breast tumours”, IEEE Trans. Microw. Theory Tech. 1990, 38, 791–793
  5. S. Mouty, B. Bocquet, R. Ringot, N. Rocourt, P. Devos, “Microwave radiometric imaging (MWI) for the characterisation of breast tumours”, Eur. Phys. J. Appl. Phys. 2000, 10, 73–78
  6. P.M. Meaney, M.W. Fanning, D. Li, S.P. Poplack, K.D. Paulsen, “A clinical prototype for active microwave imaging of the breast”, IEEE Trans. Microw. Theory Tech. 2000, 48, 1841–1853
  7. M. Ambrosanio, P. Kosmas, V. Pascazio, “A Multithreshold Iterative DBIM-Based Algorithm for the Imaging of Heterogeneous Breast Tissues”, IEEE Trans. Biomed. Eng. 2018, 66, 509–520
  8. M. Maffongelli, S. Poretti, A. Salvadè, R. Monleone, C. Pagnamenta, A. Fedeli, M. Pastorino, A. Randazzo, “Design and experimental test of a microwave system for quantitative biomedical imaging”, Proceedings of the 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Rome, Italy, 11–13 June 2018; pp. 1–6
  9. S.P. Rana, M. Dey, G. Tiberi, L. Sani, A. Vispa, G. Raspa, M. Duranti, M. Ghavami, S. Dudley, “Machine Learning Approaches for Automated Lesion Detection in Microwave Breast Imaging”, Clinical Data. Sci. Rep. 2019, 9, 10510 O.M. Bucci, G. Bellizzi, A. Borgia, S. Costanzo, L. Crocco, G. Di Massa, R. Scapaticci, “Experimental framework for magnetic nanoparticles enhanced breast cancer microwave imaging”, IEEE Access 2017, 5, 16332–16340
  10. S. C. Hagness, A. Taflove, J. E. Bridges, “Two-Dimensional FDTD Analysis of a pulsed Microwave Confocal System for Breast Cancer Detection: Fixed-Focus and Antenna-Array Sensors,” in IEEE Trans. On Biomed. Eng., vol. 45, no. 12, pp. 1470-1479, Dec. 1998
  11. S. C. Hagness, A. Taflove,